RH5885 V2 Raid card buzzer control method

Publication Date:  2014-07-01 Views:  280 Downloads:  0
Issue Description
RH5885 V2 Server ‘s Raid which has be configured is damage, or the hard disk is pulled out or replaced, etc, 2208 Raid card buzzer alarm will sound.
Alarm Information
buzzer alarm will sound.
Handling Process
1.When the RH5885server is starting, press "Ctrl + H" login 2208Raid Card configuration interface. Click "Start". As shown in Figure 1.

Figure 1
2.Get into Raid control Interface as shown in Figure 2, click "Controller Properties".

Figure 2
3.click“Next”, as shown in Figure 3.

Figure 3
4.click“Next”, as shown in Figure 4.

Figure 4
4.As shown in Figure 5, can choose the“Alarm Control”selection.
enable:turn on Buzzer.
disable:turn off Buzzer.
silence:Buzzer silence.
Click “Submit”。

Figure 5
Root Cause
RH5885 V2 Server ‘s Raid which has be configured is damage, or the hard disk is pulled out or replaced, etc
Suggestions
RH5885 V2 Server's Raid which has be configured is damage, or the hard disk is pulled out or replaced, etc, 2208 Raid card buzzer alarm will sound. It could turn off the buzzer switch by the Raid Card Controller.

END