High CPU on AR3260 because of SD card

Publication Date:  2014-07-30 Views:  307 Downloads:  0
Issue Description
Customer reported one issue about high CPU on AR3260 and the high task is IC
Alarm Information
Apr 30 2014 14:00:35+10:00 XXXXX %%01MON/4/CPU_USAGE_HIGH(l)[859]:The CPU is overloaded, and the tasks with top three CPU occupancy are IC(69%), TICK(10%), RSVP(1%). (CpuUsage=88%, Threshold=80%)
Handling Process
1. According to the IC task, it is used for info-center. High CPU should be relevant to log on AR3260
2. Let customer collect information to analzye the issue
• display cpu-usage     ---- Check the current cpu-usage and implement several time like last time. Give us all the output.
• Enter Diagnostic mode
[huawei] diagnose
[huawei-diagnose] display task IC    //// Check Task ID for IC
[huawei-diagnose] display task-monitor-record config      ///Check Index for IC task. it should be in Exclude Task List
[huawei-diagnose] set task-monitor-record del-exclude-task index   /// index is from output of last command
[huawei-diagnose] set task-monitor-record threshold 50 taskid taskid     ///Enable monitor task for IC process. Taskid, please check the output of command  “display task-monitor-record config”. Please wait 1 minutes.
[huawei-diagnose] display task-monitor-record     ///After 1 minutes, Check the result for IC task monitor. Please implement it for several times.
3. After get above information, we find the high CPU is because of SD0 card.
By default, all the logs are saved in SD1 card. Once there is SD0 card, logs will be saved in SD0 card.

However, AR router cannot find any directory in SD0 card

  ===============dir sd0:===============
============================================
Info: File can't be found in the directory
3,872,576 KB total (3,872,128 KB free)
============================================

Please change the log saved path to SD1 as below and check the CPU is down or not.
info-center logfile path sd1:/logfile


If the CPU goes down, Please format SD0. We doubt the file system is not created on SD0. That is why file cannot be saved in SD0.

<Huawei> format sd0

5. After customer change the logfile path. The problem is solved.
Root Cause
None
Suggestions
None

END