FAQ-If the power-on sequence of disk enclosures is not the physical connection sequence, how can I change the power-on sequence

Publication Date:  2015-07-23 Views:  171 Downloads:  0
Issue Description
If the power-on sequence of disk enclosures is not the physical connection sequence, how can I change the power-on sequence?

Solution
The example here uses one controller enclosure and four disk enclosures to clarify how to power on disk enclosures according to their physical connection sequence.

1.  The power-on sequence of disk enclosures is determined by how they were powered on for the first time. Therefore, to change the power-on sequence, you need to clear the DB data first. Clear the DB data.
On the CLI, run the clearcofferdb command.

2.  Power on the disk enclosures one by one.
  • Power on the controller enclosure and the first disk enclosure.
  • Power on the second disk enclosure.
  • Power on the third disk enclosure.
  • Power on the fourth disk enclosure.

END