What's the measure to meet the electromagnetic compatibility requirements

Publication Date:  2016-12-02 Views:  428 Downloads:  0
Issue Description
What's the measure to meet the electromagnetic compatibility requirements
Solution
To meet the previous requirements, take the following measures:

Locate the TR away from transformers, high-voltage wires, and high-current equipment, for example, at least 20 meters away from the AC transformer with the capacity greater than 10 kVA and at least 50 meters away from high-voltage wires.

Locate the TR away from high-power broadcasting transmitter, for example, at least 100 meters away from the broadcasting transmitter with the power greater than 1500 W.

If there is a mobile communication transmitter in the TR building, its interference effect must comply with local and national standards and regulations. If necessary, take measures to screen and isolate the interference.

Do not use portable wireless devices when you are near the server.

END