Huawei V2 and V3 Server RAID Controller Card User Guide 36

This document describes the appearances and features of the redundant array of independent disks (RAID) controller cards, how to configure properties for the RAID controller cards, and how to install drivers. The RAID controller cards include the LSI SAS2208, LSI SAS2308, LSI SAS3008, LSI SAS3108, LSI SoftRAID, PM8060, and PM8068.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Rebuilding RAID Data

Rebuilding RAID Data

Scenarios

If a member drive of a RAID array is faulty, RAID data rebuild is required no matter whether the failed hard drive is replaced with a new hard drive or a hot spare drive.

This rebuild happens by default when an appropriate hard drive is available, unless the RAID controller card property Auto Rebuild is set to Disable.

Procedure

  1. Access the Configuration Utility main screen. For details, see Logging In to the Configuration Utility.
  2. On the Configuration Utility main screen, choose Rebuild and press Enter.

    The hard drive list is displayed, as shown in Figure 9-54.

    Figure 9-54 Hard drive list

  3. Use and to select the hard drive for rebuilding data to, and press the space bar to confirm selection.

    The hard drive name turns red, as shown in Figure 9-55.

    You can rebuild data only from hard drives in the HOTSP, FAIL, or RBLD state.

    Figure 9-55 Selected hard drive

  4. Press F10 to rebuild data.

    A confirmation dialog box is displayed.

  5. Press Y to start the rebuild.

    When the rebuild is complete, "100% Completed" is displayed.

  6. Press Esc to exit the rebuild screen.
  7. Press Esc to exit the Configuration Utility main screen.
  8. Restart the server.