This document describes the appearances and features of the redundant array of independent disks (RAID) controller cards, how to configure properties for the RAID controller cards, and how to install drivers. The RAID controller cards include the LSI SAS2208, LSI SAS2308, LSI SAS3008, LSI SAS3108, LSI SoftRAID, PM8060, and PM8068.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Hard Drive Fault

Hard Drive Fault

Symptom

A hard drive fault occurs if any of the following occurs:

  • The hard drive fault indicator is on.
  • The hard drive activity indicator is off.
  • A hard drive fault alarm was generated.

Solution

  • Before removing a hard drive, determine its location to prevent misoperations. If another hard drive is removed, the RAID array will fail.
  • After a failed hard drive is disconnected from the hard drive backplane, wait for 30 seconds before removing it and inserting a new one. The alarm persists after a new hard drive is installed and will be cleared after the RAID array is rebuilt. Do not frequently hot-swap a hard drive to prevent new alarms.
  1. Remove the failed hard drive.
  2. Determine whether data can be restored.

    • For a RAID 0 array, data cannot be restored.

      Install a new hard drive and reconfigure the RAID array.

    • If the RAID array has a hot spare drive, the hot spare drive automatically replaces the failed hard drive and rebuilds data.
    • If the RAID array with redundancy does not have a hot spare drive, install a new hard drive.

  3. Install a new hard drive.

    LSI SoftRAID requires the new hard drive to be an empty drive.

    • If the RAID array has a hot spare drive, the new hard drive automatically becomes a new hot spare drive. No further action is required.
    • If the RAID array with redundancy does not have a hot spare drive, data is automatically rebuilt on the new hard drive. No further action is required.