Huawei V2 and V3 Server RAID Controller Card User Guide 36

This document describes the appearances and features of the redundant array of independent disks (RAID) controller cards, how to configure properties for the RAID controller cards, and how to install drivers. The RAID controller cards include the LSI SAS2208, LSI SAS2308, LSI SAS3008, LSI SAS3108, LSI SoftRAID, PM8060, and PM8068.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Drive Roaming

Drive Roaming

After migrating physical drives within a controller, the controller can automatically identify the relocated physical drives and logically relocate them to virtual drives of the same drive group. Drive roaming requires the server system to be shut down.

To implement drive roaming:

  1. Shut down the OS.
  2. Disconnect the power cable.
  3. Insert a physical drive into its new position in the backplane.
  4. Check that the drive is properly installed.
  5. Power on the server.
  6. Check that the controller can detect the RAID configuration from the physical drive configuration.