Huawei V2 and V3 Server RAID Controller Card User Guide 36

This document describes the appearances and features of the redundant array of independent disks (RAID) controller cards, how to configure properties for the RAID controller cards, and how to install drivers. The RAID controller cards include the LSI SAS2208, LSI SAS2308, LSI SAS3008, LSI SAS3108, LSI SoftRAID, PM8060, and PM8068.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Hot Spares

Hot Spares

Hot spare drives are used for replacing faulty member drives and taking over the data on them.

The LSI SAS3008IR supports a maximum of two global hot spare drives. When one or two member drives of the same type as hot spare drives fail, they are replaced by hot spare drives to prevent data loss or fault deterioration.

The LSI SAS3008IR does not support emergency spares and dedicated hot spare drives.

For details about how to configure hot spare drives, see Configuring a Hot Spare Drive.

The HDDs and SSDs cannot be used as the hot spare drives of each other.