This document describes the appearances and features of the redundant array of independent disks (RAID) controller cards, how to configure properties for the RAID controller cards, and how to install drivers. The RAID controller cards include the LSI SAS2208, LSI SAS2308, LSI SAS3008, LSI SAS3108, LSI SoftRAID, PM8060, and PM8068.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking Consistency

Checking Consistency

Scenarios

A consistency check verifies inconsistent data between mirrored hard drives or between the primary data blocks and redundant data.

The LSI SoftRAID Configuration Utility provides two data consistency check methods:

  • On the LSI SoftRAID Configuration Utility main screen, select Check Consistency.
  • Choose Objects > Virtual Drives and select a virtual drive.

The procedures and displayed information of the two methods are similar. This section describes the first method.

Procedure

  1. Access the Configuration Utility main screen. For details, see Logging In to the Configuration Utility.
  2. On the Configuration Utility main screen, choose Check Consistency and press Enter.

    The virtual drive list is displayed, as shown in Figure 9-56.

    Figure 9-56 Virtual drive list

  3. Press the space bar to select the virtual drive for a consistency check, and press F10.

    The consistency check confirmation dialog box is displayed.

    Only virtual drives in the Optimal state can be checked.

  4. Select Yes and press Enter to start the consistency check.

    When the consistency check is complete, "100% Completed" is displayed.

  5. Press Esc to exit the consistency check screen.
  6. Press Esc to exit the Configuration Utility main screen.
  7. Restart the server.