Huawei V2 and V3 Server RAID Controller Card User Guide 36

This document describes the appearances and features of the redundant array of independent disks (RAID) controller cards, how to configure properties for the RAID controller cards, and how to install drivers. The RAID controller cards include the LSI SAS2208, LSI SAS2308, LSI SAS3008, LSI SAS3108, LSI SoftRAID, PM8060, and PM8068.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Viewing Virtual Drive Information

Viewing Virtual Drive Information

Procedure

  1. Access the Configuration Utility main screen. For details, see Logging In to the Configuration Utility.
  2. On the Adapter Properties screen, select RAID Properties and press Enter.

    The Select New Volume Type screen is displayed, as shown in Figure 5-44. Table 5-14 describes the parameters on the screen.

    Figure 5-44 Select New Volume Type screen
    Table 5-14 Operation descriptions

    Operation

    Description

    View Existing Volume

    Views the existing configuration.

    This option is available only when RAID arrays have been created for the LSI SAS2308.

    Create RAID 1 Volume

    Creates a RAID 1 array.

    Create RAID 1E/10 Volume

    Creates a RAID 1E or 10 array.

    Create RAID 0 Volume

    Creates a RAID 0 array.

  3. Select View Existing Volume and press Enter.

    Existing RAID arrays are displayed, as shown in Figure 5-45. Table 5-15 describes the parameters on this screen.

    Figure 5-45 View Volume screen
    Table 5-15 Parameters

    Parameter

    Description

    Volume

    RAID array number.

    Identifier

    RAID array name.

    Type

    RAID level.

    Size

    RAID array capacity.

    Status

    RAID array status.

    Task

    Task of the RAID array.

    Slot Num

    Hard drive slot number.

    Device Identifier

    Hard drive name.

    RAID Disk

    Indicates whether the hard drive is a member of the RAID array.

    Hot Spr

    Indicates whether the drive is a hot spare drive.

    Drive Status

    Drive status.

    Pred Fail

    Indicates whether the hard drive is to be identified as failed by the controller card.

    Disk Size

    Hard drive capacity.

    If the LSI SAS2308 has more than one RAID array, press Alt+N to view information about other RAID arrays.