S5700 Series Switches Hardware Description

This document provides an overall description of the S5700 hardware, helping you obtain detailed information about each chassis, card, power module, fan module, cable, and optical module.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
S5700-28X-LI-AC

S5700-28X-LI-AC

Version Mapping

Table 4-64 lists the mapping between the S5700-28X-LI-AC chassis and software versions.

Table 4-64 Version mapping

Series

Model

Software Version
S5700-LI S5700-28X-LI-AC

V200R002C00 to V200R012C00 versions

NOTE:
This model does not match V200R003C02, V200R003C10, V200R005C00SPC500, V200R005C01, V200R005C02, V200R005C03, or V200R007C10.

Appearance and Structure

Figure 4-25 S5700-28X-LI-AC appearance
1 Twenty-four 10/100/1000BASE-T ports 2 Four 10GE SFP+ ports
3 One mini USB port 4 One console port
5 Ground screw
NOTE:
It is used with a ground cable.
6 RPS socket
NOTE:

It is used with an RPS cable, which is not hot swappable.

7 Jack for AC power cable locking strap
NOTE:
The AC power cable locking strap is not delivered with the switch.
8 AC socket
NOTE:

It is used with an AC power cable.

Port Description

10/100/1000BASE-T port
A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s, and must use an Ethernet cable. Table 4-65 describes the attributes of a 10/100/1000BASE-T Ethernet electrical port.
Table 4-65 Attributes of a 10/100/1000BASE-T Ethernet electrical port

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3, IEEE802.3u, IEEE802.3ab

Working mode

10/100/1000 Mbit/s auto-sensing

Maximum transmission distance

100 m

10GE SFP+ port
A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. Table 4-66 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 4-66 Attributes of a 10GE SFP+ port

Attribute

Description

Connector type

LC/PC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ae

Working mode

GE/10GE auto-sensing

Console port
The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4-67.
Table 4-67 Attributes of a console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS-232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

Mini USB port

The mini USB port is connected to a console for on-site configuration. When both the Mini USB and console port have a cable connected, only the Mini USB port works.

Indicator Description

NOTE:
In V200R007 and later versions, you can hold down the mode switch button for 6s and release it to start the web initial login mode. Either of the following situations will occur:
  • If the switch has no configuration file, the system attempts to enter the web initial login mode. In this mode, the status of mode indicators is as follows:
    • If the system enters the web initial login mode successfully, all mode indicators turn green and stay on for a maximum of 10 minutes.
    • If the system fails to enter the initial login mode, all mode indicators fast blink for 10 seconds and then restore to the default status.
  • If the switch has a configuration file, the system cannot enter the web initial login mode. In this case, all mode indicators fast blink for 10s, and then return to the default states.
Figure 4-26 Indicators on the S5700-28X-LI-AC

Table 4-68 Description of indicators on the switch

Number

Indicator/Button

Color

Description

1

PWR: internal power supply indicator

-

Off: The switch is powered off.

Green

Steady on: The switch is powered on.

Yellow

Steady on: The built-in power module is faulty, and the switch is powered by the RPS system.

2

RPS: RPS power supply indicator

-

Off: No RPS is connected to the switch.

Green

  • Steady on: The RPS is in cold backup state.

  • Blinking: The RPS is providing power for another device.

Yellow

Blinking: The RPS is providing power for the switch and the built-in power module of the switch is faulty.

3

SYS: system status indicator

-

Off: The system is not running.

Green

Fast blinking:
  • The system is starting.
  • The system is copying the system software and configuration file from a USB flash drive during a USB-based upgrade (only applicable to S5701-28X-LI-AC).

Slow blinking: The system is running normally.

Yellow

Blinking:
  • The switch is in sleeping mode.
  • During a USB-based upgrade, this indicator blinks after the switch downloads required files and restarts. At this time, the upgrade is successful and you can remove the USB flash drive (only applicable to S5701-28X-LI-AC).
NOTE:
The system can wake from the sleeping state if you press the MODE button. The S5700-10P-LI-AC does not support the sleeping function.

Red

  • Steady on: The system does not work normally after registration, or a fan or temperature alarm has been generated.

  • Blinking: The system cannot be upgraded after a USB flash drive is inserted. The USB-based upgrade failed (only applicable to S5701-28X-LI-AC).

4

STAT: status indicator

Green

  • Off: The status mode is not selected.

  • Steady on: The status mode (default mode) is selected. If the status mode is selected, the service port indicator shows the port link or activity state.
5

SPED: speed indicator

Green

  • Off: The speed mode is not selected.

  • Steady on: The speed mode is selected. If the speed mode is selected, the service port indicator shows the port speed state. After 45 seconds, the service port indicators automatically restore to the status mode.

6

STCK: stack indicator

NOTE:
This indicator has different states and meanings in different versions. Here are the indicator states and meaning in versions earlier than V200R003C00.

Green

  • Off: The stack mode is not selected.
  • Steady on: The service port indicators show the stack information. After 45 seconds, the service port indicators automatically restore to the status mode.

  • Blinking: The switch is the master switch in a stack or a standalone switch.

STCK: stack indicator

NOTE:
This indicator has different states and meanings in different versions. Here are the indicator states and meaning in V200R003C00 and later versions.

Green

If you are not changing the indicator mode (default):
  • Off: The switch is in stack standby or slave state or the stacking function is not enabled on the switch.
  • Blinking: The switch is a stack master switch or a standalone switch with the stacking function enabled.

If you are changing the indicator mode:
  • Off: The stack mode is not selected.
  • Steady on: The switch is a standby or slave switch in a stack, and the service port indicators show the stack ID of the switch.

  • Blinking: The switch is the master switch in a stack or a standalone switch, and the service port indicators show the stack ID of the master switch.

After 45 seconds, the service port indicators automatically restore to the status mode.
7

MODE: mode switch button

-

  • When you press this button once, the service port indicators change to the speed mode and show the speed of each service port.
  • When you press this button a second time, the service port indicators change to the stack mode and show the stack ID of the local switch.
  • When you press this button a third time, the service port indicators restore to the default mode, and the STAT indicator turns green.

If you do not press the MODE button within 45 seconds, the service port indicators restore to the default mode. In this case, the STAT indicator is steady green, the SPED indicator is off, and the STCK indicator is off or blinking green.

8

Service port indicator

  • GE electrical ports: The ports are numbered from bottom to top and left to right, starting with 1.
  • SFP/SFP+ optical ports: Each port has an indicator above it.

Meanings of service port indicators vary in different modes. For details, see Table 4-69.

9

Mini USB indicator

Green

  • Off: The Mini USB port is not active, and the console port is active.

  • Steady on: The Mini USB port is active.

When this indicator is on, the console indicator is off.

10

Console indicator

Green

  • Off: The console port is not active, and the Mini USB port is active.

  • Steady on (default): The console port is active.

When this LED is on, the Mini USB port indicator is off.

Table 4-69 Description of service port indicators in different modes (one indicator for each port)
Display Mode Color Status Description
Status - Off The port is not connected or has been shut down.
Green Steady on A link has been established on the port.
Green Blinking The port is sending or receiving data.
Speed - Off The port is not connected or has been shut down.
Green Steady on

10M/100M/1000M port: The port is operating at 10/100 Mbit/s.

1000M/10GE port: The port is operating at 1000 Mbit/s.

Green Blinking

10M/100M/1000M port: The port is operating at 1000 Mbit/s.

1000M/10GE port: The port is operating at 10 Gbit/s.

Stack - Off Port indicators do not show the stack ID of the switch.
Green Steady on
The switch is not the master switch in a stack.
  • If the indicator of a port is steady on, the number of this port is the stack ID of the switch.

  • If the indicators of ports 1 to 9 are steady on, the stack ID of the switch is 0.

Green Blinking
The switch is the master switch in a stack.
  • If the indicator of a port is blinking, the number of this port is the stack ID of the switch.

  • If the indicators of ports 1 to 9 are blinking, the stack ID of the switch is 0.

Power Supply Configuration

The S5700-28X-LI-AC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.

Figure 4-27 shows the power supply mode of a built-in AC power module. The built-in AC power module (PWR) receives power from an external power source and provides a 12 V output to the chassis.
Figure 4-27 Power supply mode of a built-in AC power module

L: live wire

N: neutral wire

PGND: protection ground

GND: 12 V reference ground

Heat Dissipation

The S5700-28X-LI-AC has a built-in fan for forced air cooling. The airflow direction is left-to-right.

Technical Specifications

Table 4-70 lists technical specifications of the S5700-28X-LI-AC.

Table 4-70 Technical specifications

Item

Description

Memory (RAM)

256 MB

Flash

200 MB

Mean time between failures (MTBF)

68.95 years
Mean time to repair (MTTR)

2 hours

Availability

> 0.99999

Service port surge protection

Common mode: ±6 kV

Power supply surge protection

±6 kV in differential mode, ±6 kV in common mode

Dimensions (H x W x D)

43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)

Weight (with packaging)

3.4 kg (7.5 lb)

Stack ports

Four uplink 10GE SFP+ ports

RTC

Supported

RPS

Supported

PoE

Not supported

Rated voltage range

100 V AC to 240 V AC, 50/60 Hz

Maximum voltage range

90 V AC to 264 V AC, 47 Hz to 63 Hz

Maximum power consumption (100% throughput, full speed of fans)

41 W
Typical power consumption (30% of traffic load)
  • Tested according to ATIS standard
  • EEE enabled
  • No PoE power consumption
29.7 W

Operating temperature

0°C to 50°C (32°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Storage temperature

-40°C to +70°C (-40°F to +158°F)

Noise under normal temperature (27°C, sound power)

< 44.9 dB(A)

Relative humidity

5% to 95%, noncondensing

Operating altitude

0-5000 m (0-16404 ft.)

Certification

  • EMC certification
  • Safety certification
  • Manufacturing certification

Part number