S5731-L4P2HT-RUA
Overview
Item | Details |
---|---|
Description | S5731-L4P2HT-RUA (4*10/100/1000BASE-T ports, PoE++, 1*GE hybrid optical-electrical SFP port, 1*10/100/1000BASE-T port, PoE input) |
Part Number | 98011776 |
Model | S5731-L4P2HT-RUA |
First supported version | V200R021C10SPC500 |
Components
1 |
One RST button NOTICE:
To reset the device, press and hold down the button for less than 6s. |
2 |
Four 10/100/1000BASE-T PoE++ ports |
3 |
One 10/100/1000BASE-T port NOTE:
The port is an uplink port. The port can receive PoE power from a central switch through an Ethernet cable or the first-generation hybrid cable. |
4 |
One 1000BASE-X hybrid optical-electrical port NOTE:
The port is an uplink port. The port can receive PoE power from a central switch through the second-generation hybrid cable. When using a hybrid cable to receive power, you must use the pigtails or jumpers and hybrid modules matching the second-generation hybrid cable. |
5 |
Power adapter socket NOTE:
The power adapter is not delivered with the device by default and can be purchased separately (part number: 02221024). |
6 |
Ground screw |
Ports
Port | Connector Type | Description | Available Components |
---|---|---|---|
10/100/1000BASE-T PoE++ port | RJ45 | A 10/100/1000BASE-T PoE++ Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s. The port supports the PoE function. |
|
10/100/1000BASE-T port | RJ45 | A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s. It can receive PoE power from a central switch through an Ethernet cable. |
|
1000BASE-X hybrid optical-electrical port | SFP | A 1000BASE-X hybrid optical-electrical port can send and receive data at 1000 Mbit/s. It can receive PoE power from a central switch through a hybrid cable. |
Indicators and Buttons
The S5731-L4P2HT-RUA has similar indicators to those on the S5731-L8P2HT-RUA. For details, see the S5731-L8P2HT-RUA.
Power Supply System
The remote unit supports the following power supply modes:
- Powered by an external power adapter (separately purchased)
- Powered by a central switch using an Ethernet cable of Cat5e or higher category (occupies the uplink electrical port, which is used for both PoE power input and data transmission)
- Powered by a central switch using the second-generation hybrid cable (occupies the uplink hybrid optical-electrical port, which is used for both PoE power input and data transmission)
- Powered by a central switch using the first-generation hybrid cable (occupies the uplink electrical port and uplink hybrid optical-electrical port. The uplink electrical port is used for PoE power input, and the uplink hybrid optical-electrical port is used for data transmission.)
When different power supply modes are used at the same time, the system preferentially uses the power adapter for power supply. The cold backup mode is used between different power supply modes and cannot supply power to the remote unit at the same time. The two uplink ports have no default priority, and the connection time is used as the priority.
The remote unit can provide PoE power for external PDs. The PoE power supply capability varies according to the power supply mode.
Power Supply Mode |
Available PoE Power |
Maximum Number of Ports (Fully Loaded) |
Remark |
---|---|---|---|
Powered by an external power adapter |
77 W |
|
- |
Powered by a central switch |
Forcible power supply disabled (default): max 60 W |
|
|
Forcible power supply enabled: max 83 W |
|
When the remote unit is powered by the central switch, the total power consumption of the remote unit and its connected PDs cannot exceed 71.3 W. If the power consumption exceeds 71.3 W, the remote unit and its connected PDs will be powered off and restarted.
When the remote unit is powered by the central switch, the maximum available PoE power in the preceding table can be provided only when the following conditions are met:
- When forcible power supply is disabled by default:
- The PoE output of the central switch must comply with the 802.3bt class8 standard.
- When forcible power supply is enabled (using the poe force-power port command):
- The PoE output of the central switch must comply with the 802.3bt class8 standard.
- The central switch and the remote unit must be connected for a short distance (less than 8 m, with the line loss ignored). If the distance between the central switch and the remote unit is longer than 8 m and the PD is supplied with power based on the maximum power supply capability displayed on the central switch, the remote unit and the connected PD may be powered off and restarted.
- The output voltage of the power module used by the central switch cannot be lower than 55.5 V.
The actual available PoE power provided by the remote unit is calculated based on the cabling distance between the central switch and the remote unit, the cabling distance between the remote unit and the connected PD, the maximum power consumption of the remote unit, the PoE output voltage of the central switch, and PoE class level output by the central switch.
If the power output of the remote unit is manually configured to comply with 802.3at or 802.3af, the PD connected to the remote unit will be power-cycled when the remote unit is reset due to a cause other than power-off.
Heat Dissipation System
The remote unit has no fans and uses natural heat dissipation.
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 38.0 mm x 185.0 mm x 115.0 mm (1.5 in. x 7.28 in. x 4.53 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 38.0 mm x 185.0 mm x 115.0 mm (1.5 in. x 7.28 in. x 4.53 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 82.0 mm x 270.0 mm x 178.0 mm (3.23 in. x 10.63 in. x 7.01 in.) |
Chassis height [U] | 0.855 U |
Weight without packaging [kg(lb)] | 0.60 kg (1.32 lb) |
Weight with packaging [kg(lb)] | 0.81 kg (1.79 lb) |
Typical power consumption [W] | 6.82 W (device) 8.30 W (device + power adapter) |
Typical heat dissipation [BTU/hour] | 23.27 (device) 28.32 (device + power adapter) |
Maximum power consumption [W] |
|
Maximum heat dissipation [BTU/hour] |
|
Static power consumption [W] | 4.88 W |
MTBF [year] | 73.98 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | Noise-free (no fans): < 30 |
Noise at normal temperature (acoustic pressure) [dB(A)] | Noise-free (no fans): < 20 |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 0 |
Redundant power supply | Cold backup of uplink hybrid optical-electrical ports or electrical ports and power adapters, cold backup of uplink hybrid optical-electrical ports and electrical ports, and preferential power supply by power adapters (By default, no power adapter is provided, and the power adapter 02221024 can be used.) |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5905.44-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (721.78 ft.). The device cannot start when the temperature is lower than 0°C (32°F). The operating temperature of a device ranges from -5°C to +45°C (23°F to 113°F) when the device uses the following optical modules: - GE optical modules with a transmission distance of less than or equal to 10 km |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode |
|
Rated input voltage [V] | Power adapter input: 100–240 V AC; 50/60 Hz PoE input: 56 V DC |
Input voltage range [V] | Power adapter input: 90–290 V AC; 47–63 Hz PoE input: 54–57 V DC |
Maximum input current [A] | 1.8 A |
Memory | -- |
Flash memory | -- |
Console port | Not supported |
Eth Management port | Not supported |
USB | Not supported |
RTC | Not supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±6 kV |
Power supply surge protection [kV] | Power adapter: ±6 kV in differential mode and ±6 kV in common mode |
Types of fans | None |
Heat dissipation mode | Natural heat dissipation |
Airflow direction | - |
PoE | Supported |
Certification | EMC certification Safety certification Manufacturing certification |