S5700 Series Switches Hardware Description

This document provides an overall description of the S5700 hardware, helping you obtain detailed information about each chassis, card, power module, fan module, cable, and optical module.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
3-Pin AC Power Cable (Phoenix Connector)

3-Pin AC Power Cable (Phoenix Connector)

Appearance and Structure

Figure 9-29 shows the appearance and structure of the 3-pin AC power cable and the Phoenix connector.

Figure 9-29 Structure of a 3-pin AC power cable and Phoenix connector

There is a risk of electric shock when handling the Phoenix connector. To avoid electric shock, ensure that wires are connected in the following sequences: red wire (live wire) connects to L; blue wire (neutral wire) connects to N; yellow/green wire (ground cable) connects to PE. In special circumstances, comply with local regulations or customer requirements.

The power cable and Phoenix connector need to be connected onsite. Ensure that there are no exposed metal parts after the power cable is connected to the Phoenix connector.

Specifications

Table 9-15 lists the specifications of the 3-pin AC power cable.

Table 9-15 Specifications of a 3-pin AC power cable

Minimum Conductor Cross-Sectional Area (for the Power Cable Delivered with the Switch)

Maximum Conductor Cross-Sectional Area

0.75 mm2 or 18 AWG

NOTE:
The minimum conductor cross-sectional area for the S5720I-28X-PWH-SI-AC series switches is 1.25 mm2 or 16 AWG.

3 mm2 or 12 AWG

Connection

One end of the 3-pin AC power cable is used with the Phoenix connector and connected to the AC input port of the S5720I-SI. The other end needs to be made onsite. You can make the power cables according to site requirements and connect the cables to the AC power supply system.