S5700 Series Switches Hardware Description

This document provides an overall description of the S5700 hardware, helping you obtain detailed information about each chassis, card, power module, fan module, cable, and optical module.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
S5700S-28P-LI-AC

S5700S-28P-LI-AC

Version Mapping

Table 4-130 lists the mapping between the S5700S-28P-LI-AC chassis and software versions.

Table 4-130 Version mapping

Series

Model

Software Version
S5700S-LI S5700S-28P-LI-AC

V200R001C00 to V200R012C00 versions

NOTE:
This model does not match V200R001C01, V200R003C02, V200R003C10, V200R005C00SPC500, V200R005C01, V200R005C02, V200R005C03, or V200R007C10.

Appearance and Structure

Figure 4-51 S5700S-28P-LI-AC appearance
1 Twenty-four 10/100/1000BASE-T ports 2 Four 1000BASE-X ports
3 One mini USB port 4 One console port
5 Ground screw
NOTE:
It is used with a ground cable.
6 RPS socket
NOTE:

It is used with an RPS cable, which is not hot swappable.

7 Jack for AC power cable locking strap
NOTE:
The AC power cable locking strap is not delivered with the switch.
8 AC socket
NOTE:

It is used with an AC power cable.

Port Description

10/100/1000BASE-T port
A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s, and must use an Ethernet cable. Table 4-131 describes the attributes of a 10/100/1000BASE-T Ethernet electrical port.
Table 4-131 Attributes of a 10/100/1000BASE-T Ethernet electrical port

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3, IEEE802.3u, IEEE802.3ab

Working mode

10/100/1000 Mbit/s auto-sensing

Maximum transmission distance

100 m

1000BASE-X port
When a 1000BASE-X port uses a GE optical module, it can only transmit and receive data at 1000 Mbit/s and does not support the 100 Mbit/s transmission speed. When a 1000BASE-X port uses a GE copper module, it can transmit and receive data at 10 Mbit/s, 100 Mbit/s, or 1000 Mbit/s. Table 4-132 describes the attributes of a 1000BASE-X Ethernet optical port.
Table 4-132 Attributes of a 1000BASE-X Ethernet optical port

Attribute

Description

Connector type

LC/PC

Optical port attributes

Depend on the module used

Standards compliance

IEEE802.3z

Console port
The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4-133.
Table 4-133 Attributes of a console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS-232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

Mini USB port

The mini USB port is connected to a console for on-site configuration. When both the Mini USB and console port have a cable connected, only the Mini USB port works.

Indicator Description

NOTE:
In V200R007 and later versions, you can hold down the mode switch button for 6s and release it to start the web initial login mode. Either of the following situations will occur:
  • If the switch has no configuration file, the system attempts to enter the web initial login mode. In this mode, the status of mode indicators is as follows:
    • If the system enters the web initial login mode successfully, all mode indicators turn green and stay on for a maximum of 10 minutes.
    • If the system fails to enter the initial login mode, all mode indicators fast blink for 10 seconds and then restore to the default status.
  • If the switch has a configuration file, the system cannot enter the web initial login mode. In this case, all mode indicators fast blink for 10s, and then return to the default states.
Figure 4-52 Indicators on the S5700S-28P-LI-AC

Table 4-134 Description of indicators on the switch

Number

Indicator/Button

Color

Description

1

PWR: built-in power module indicator

-

Off: The switch is powered off.

Green

Steady on: The switch is powered on.

Yellow

Steady on: The built-in power module is faulty, and the switch is powered by the RPS system.

2

SYS: system status indicator

-

Off: The system is not running.

Green

  • Fast blinking: The system is starting.
  • Slow blinking: The system is operating properly.

Yellow

Blinking: The system is in the sleep state.

NOTE:
The system can wake from the sleeping state if you press the MODE button.

Red

Steady on: The system does not work normally after registration, or a fan or temperature alarm has been generated.

3

STAT: status indicator

Green

  • Off: The status mode is not selected.

  • Steady on: The status mode (default mode) is selected. If the status mode is selected, the service port indicator shows the port link or activity state.
4

SPED: speed indicator

Green

  • Off: The speed mode is not selected.

  • Steady on: The speed mode is selected. If the speed mode is selected, the service port indicator shows the port speed state. After 45 seconds, the service port indicators automatically restore to the status mode.

5

STCK: stack indicator

-

Currently, the switch does not support stacking. This indicator is reserved for the stacking function.

6

MODE: mode switch button

-

  • When you press this button once, the SPED indicator turns green and the service port indicators show the speed of each service port.
  • When you press the button a second time, the STAT indicator turns green.

If you do not press the button within 45 seconds, the indicators restore to the default states. That is, the STAT indicator turns green, and the SPED and STCK indicators are off.

7

Service port indicator

  • GE electrical ports: The ports are numbered from bottom to top and left to right, starting with 1.
  • GE optical ports: Each port has an indicator above it.

Meanings of service port indicators vary in different modes. For details, see Table 4-135.

8

Mini USB indicator

Green

  • Off: The Mini USB port is not active, and the console port is active.

  • Steady on: The Mini USB port is active.

When this indicator is on, the console indicator is off.

9

Console indicator

Green

  • Off: The console port is not active, and the Mini USB port is active.

  • Steady on (default): The console port is active.

When this LED is on, the Mini USB port indicator is off.

Table 4-135 Description of service port indicators in different modes

Display Mode

Color

Description

Status

Green

  • Off: The port is not connected or has been shut down.
  • Steady on: The port is connected.

  • Blinking: The port is sending or receiving data.

Speed

Green

  • Off: The port is not connected or has been shut down.
  • Steady on:

    10M/100M/1000M port: The port is operating at 10/100 Mbit/s.

    1000M/10GE port: The port is operating at 1000 Mbit/s.

  • Blinking:

    10M/100M/1000M port: The port is operating at 1000 Mbit/s.

    1000M/10GE port: The port is operating at 10 Gbit/s.

Power Supply Configuration

The S5700S-28P-LI-AC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.

Figure 4-53 shows the power supply mode of a built-in AC power module. The built-in AC power module (PWR) receives power from an external power source and provides a 12 V output to the chassis.
Figure 4-53 Power supply mode of a built-in AC power module

L: live wire

N: neutral wire

PGND: protection ground

GND: 12 V reference ground

Heat Dissipation

The S5700S-28P-LI-AC has no fans and uses natural heat dissipation.

Technical Specifications

Table 4-136 lists technical specifications of the S5700S-28P-LI-AC.

Table 4-136 Technical specifications

Item

Description

Memory (RAM)

256 MB

Flash

  • V200R001: 64 MB
  • V200R002 and later versions: 200 MB

Mean time between failures (MTBF)

49.69 years

Mean time to repair (MTTR)

2 hours

Availability

> 0.99999

Service port surge protection

Common mode: ±6 kV

Power supply surge protection

±6 kV in differential mode, ±6 kV in common mode

Dimensions (H x W x D)

43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)

Weight (with packaging)

2.8 kg (6.17 lb)

Stack ports

Not supported

RTC

Supported

RPS

Supported

PoE

Not supported

Rated voltage range

100 V AC to 240 V AC, 50/60 Hz

Maximum voltage range

90 V AC to 264 V AC, 47 Hz to 63 Hz

Maximum power consumption (100% throughput)

24 W

Typical power consumption (30% of traffic load)
  • Tested according to ATIS standard
  • EEE enabled
  • No PoE power consumption

19.3 W

Operating temperature

0°C to 50°C (32°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The operating temperature of the switch is 0°C to 45°C (32°F to 113°F) when it uses SFP optical modules with 80 km or longer transmission distances.

Storage temperature

-40°C to +70°C (-40°F to +158°F)

Noise under normal temperature (27°C, sound power)

Noise-free (no fans)

Relative humidity

5% to 95%, noncondensing

Operating altitude

0-5000 m (0-16404 ft.)

Certification

  • EMC certification
  • Safety certification
  • Manufacturing certification

Part number

02353836
Translation