S5731-S48T4X-A (98011854)
Overview
Item | Details |
---|---|
Description | S5731-S48T4X-A (48*10/100/1000BASE-T ports, 4*10GE SFP+ ports, AC power) |
Part Number | 98011854 |
Model | S5731-S48T4X-A |
First supported version | V200R021C10SPC500 |
Components
1 |
Forty-eight 10/100/1000BASE-T ports |
2 |
Four 10GE SFP+ ports |
3 |
One console port |
4 |
One ETH management port |
5 |
One USB port |
6 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
7 |
Ground screw NOTE:
It is used with a ground cable. |
8 |
Jack for AC power cable locking strap NOTE:
The AC power cable locking strap is not delivered
with the switch. |
9 |
AC socket NOTE:
It is used with an AC power cable. |
- |
- |
Ports
Port | Connector Type | Description | Available Components |
---|---|---|---|
10/100/1000BASE-T port | RJ45 | A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s. | |
10GE SFP+ optical port | SFP+ | A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. |
|
Console port | RJ45 | The console port is connected to a console for on-site configuration. | |
USB port | USB 2.0 Type A | The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0. USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives. |
USB flash drive |
ETH management port | RJ45 | You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. |
Indicators and Buttons
No. |
Indicator |
Name |
Color |
Status |
Description |
---|---|---|---|---|---|
1 |
PWR |
Power module indicator |
- |
Off |
The switch is powered off. |
Green |
Steady on |
The system power supply is normal. |
|||
2 |
SYS |
System status indicator |
- |
Off |
The system is not running. |
Green |
Fast blinking |
The system is starting. |
|||
Green |
Steady on |
During the system startup preparation phase, the SYS indicator is steady green, which lasts for a maximum of 30 seconds. |
|||
Green |
Slow blinking |
The system is running normally. |
|||
Red |
Steady on |
The system does not work normally after registration, or a fan alarm or a temperature alarm has been generated. |
|||
3 |
MST |
Stack indicator |
- |
Off |
|
Green |
Steady on |
The stack mode is selected. The switch is a standby or slave switch in a stack, and the service port indicators show the stack ID of the switch. |
|||
Green |
Blinking |
|
|||
4 |
SPEED |
Speed indicator |
- |
Off |
The speed mode is not selected. |
Green |
Steady on |
The speed mode is selected, and service port indicators show the speed of each port. |
|||
5 |
MODE |
Mode switch button |
- |
- |
If you do not press the MODE button within 45 seconds, the service port indicators restore to the default mode. In this case, the SPEED indicator is off. NOTE:
Hold down the mode switch button for 6s and release it to start the web initial login mode. Either of the following situations will occur:
|
6 |
- |
Electrical service port indicator (one indicator for each port) |
Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. |
Meanings of service port indicators vary in different modes. For details, see Table 4-1242 and Table 4-1243. |
|
Optical service port indicator (two indicators for each port) |
Each optical port has two single-color indicators. The one on the left is the ACT indicator (yellow), and the one on the right is the LINK indicator (green). Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. |
||||
7 |
ID |
ID indicator |
- |
Off |
The ID indicator is not used (default state). |
Blue |
Steady on |
The indicator identifies the switch to maintain. The ID indicator can be turned on or off remotely to help field engineers find the switch to maintain. |
|||
8 |
L/A |
ETH port indicator |
- |
Off |
The ETH port is not connected. |
Green |
Steady on |
The ETH port is connected. |
|||
Green |
Blinking |
The ETH port is sending or receiving data. |
|||
9 |
USB |
USB-based deployment indicator |
- |
Off |
|
Green |
Steady on |
A USB-based deployment has been completed. |
|||
Green |
Blinking |
The system is reading data from a USB flash drive. |
|||
Yellow |
Steady on |
The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch. |
|||
Red |
Blinking |
An error has occurred when the system is executing the configuration file or reading data from the USB flash drive. |
Display Mode |
Color |
Status |
Description |
---|---|---|---|
Default mode |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
A link has been established on the port. |
|
Green |
Blinking |
The port is sending or receiving data. |
|
MST stack mode |
- |
Off |
Port indicators do not show the stack ID of the switch. |
Green |
Steady on |
The switch is not the master switch in a stack.
|
|
Green |
Blinking |
The switch is the master switch in a stack.
|
|
Speed mode |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
10M/100M/1000M port: The port is operating at 10 Mbit/s or 100 Mbit/s. |
|
Green |
Blinking |
10M/100M/1000M port: The port is operating at 1000 Mbit/s. |
Display Mode |
Color |
Status |
Description |
---|---|---|---|
Default mode (LINK indicator) |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
A link has been established on the port. |
|
Default mode (ACT indicator) |
- |
Off |
The port is not connected or has been shut down, or no data is transmitted or received. |
Yellow |
Blinking |
The port is sending or receiving data. |
|
Speed mode (LINK indicator) |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
1000M/10GE port: The port is operating at 1000 Mbit/s. |
|
Green |
Blinking |
1000M/10GE port: The port is operating at 10 Gbit/s. 1000M port: The port is operating at 1000 Mbit/s. |
Power Supply System
The switch has a built-in AC power module and does not support pluggable power modules.
Heat Dissipation System
The switch has two built-in fans for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 355.0 mm (3.54 in. x 21.65 in. x 13.98 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 3.21 kg (7.08 lb) |
Weight with packaging [kg(lb)] | 4.57 kg (10.08 lb) |
Typical power consumption [W] | 76 W |
Typical heat dissipation [BTU/hour] | 259.32 BTU/hour |
Maximum power consumption [W] | 102 W |
Maximum heat dissipation [BTU/hour] | 348.03 BTU/hour |
Static power consumption [W] | 48 W |
MTBF [years] | 43.17 years |
MTTR [hours] | 2 hours |
Availability | > 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 44.90 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 31.21 dB(A) |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 2 |
Redundant power supply | Not supported |
Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). The operating temperature of the switch is -5°C to +45°C (23°F to 113°F) when 10GE SFP+ optical modules with 40 km or longer transmission distances are used. |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | AC built-in |
Rated input voltage [V] | AC input: 100 V AC to 240 V AC, 50/60 Hz |
Input voltage range [V] | AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz |
Maximum input current [A] | 3 A |
Memory | 2 GB |
Flash memory | 1 GB in total. To view the available flash memory size, run the display version command. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] | ±6 kV in differential mode, ±6 kV in common mode |
Ingress protection level (dustproof/waterproof) | IP20 |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from left and front, air exhaustion from right |
PoE | Not supported |
Certification | EMC certification Safety certification Manufacturing certification |