S5700-26X-SI-12S-AC
Version Mapping
Table 4-445 lists the mapping between the S5700-26X-SI-12S-AC chassis and software versions.
Appearance and Structure
1 |
Twelve 100/1000BASE-X ports |
2 |
Twelve 10/100/1000BASE-T ports |
3 |
Two 10GE SFP+ ports Applicable modules and cables:
|
4 |
One ETH management port |
5 |
One console port |
6 |
One USB port |
7 |
Ground screw NOTE:
It is used with a ground cable. |
8 |
RPS socket NOTE:
It is used with an RPS cable, which is not hot swappable. |
9 |
Jack for AC power cable locking strap NOTE:
The AC power cable locking strap is not delivered
with the switch. |
10 |
AC socket NOTE:
It is used with an AC power cable. |
Port Description
100/1000BASE-X port
10/100/1000BASE-T port
10GE SFP+ port
Console port
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
Number |
Indicator/Button |
Color |
Description |
---|---|---|---|
1 |
PWR: power supply indicator |
- |
Off: The switch is powered off. |
Green |
Steady on: The switch is powered on. |
||
Yellow |
Steady on: The built-in power module is faulty, and the switch is powered by the RPS system. |
||
2 |
RPS: RPS power supply indicator |
- |
Off: No RPS is connected to the switch. |
Green |
|
||
Yellow |
Blinking: The RPS is providing power for the switch and the built-in power module of the switch is faulty. |
||
3 |
SYS: system status indicator |
- |
Off: The system is not running. |
Green |
|
||
Yellow |
Blinking: The system has been successfully upgraded using a USB flash drive and the switch has restarted. You can remove the USB flash drive from the switch. |
||
Red |
|
||
4 |
STAT: status indicator |
Green |
|
5 |
SPED: speed indicator |
Green |
|
6 |
MODE: mode switch button |
- |
If you do not press the button within 45 seconds, the indicators restore to the default status. That is, the STAT indicator turns green, and the SPED indicator is off. |
7 |
Service port indicator
|
Meanings of service port indicators vary in different modes. For details, see Table 4-452. |
|
8 |
ETH indicator |
Green |
|
Display Mode |
Color |
Status |
Description |
---|---|---|---|
Status |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
A link has been established on the port. |
|
Green |
Blinking |
The port is sending or receiving data. |
|
Speed |
- |
Off |
The port is not connected or has been shut down. |
Green |
Steady on |
10M/100M/1000M port: The port is operating at 10/100 Mbit/s. 1000M/10GE port: The port is operating at 1000 Mbit/s. |
|
Green |
Blinking |
10M/100M/1000M port: The port is operating at 1000 Mbit/s. 1000M/10GE port: The port is operating at 10 Gbit/s. |
|
Stack |
- |
Off |
Port indicators do not show the stack ID of the switch. |
Green |
Steady on |
The switch is not the master switch in a stack.
|
|
Green |
Blinking |
The switch is the master switch in a stack.
|
Power Supply Configuration
The S5700-26X-SI-12S-AC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.
Heat Dissipation
The S5700-26X-SI-12S-AC has two built-in fans for forced air cooling. The airflow direction is left-to-right.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-453 lists technical specifications of the S5700-26X-SI-12S-AC.
Item |
Description |
---|---|
Memory (RAM) |
256 MB |
Flash |
200 MB |
Mean time between failures (MTBF) |
91.74 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±6 kV |
Power supply surge protection |
±6 kV in differential mode, ±6 kV in common mode |
Dimensions (H x W x D) |
43.6 mm x 442.0 mm x 310.0 mm (1.72 in. x 17.4 in. x 12.2 in.) |
Weight |
≤ 5 kg (11.02 lb) |
Stack ports |
Not supported |
RPS |
Supported |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz |
Maximum power consumption (100% throughput, full speed of fans) |
42.3 W |
Operating temperature |
0°C to 50°C (32°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 56.3 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
02354039 |