S6730-H24X6C (02352FSG/02352FSG-001/02352FSG-005/02353GFC/02353GFC-001/02353GFC-003)
Version Mapping
Table 4-187 lists the mapping between the S6730-H24X6C chassis and software versions.
Series |
Model |
Software Version |
---|---|---|
S6730-H |
S6730-H24X6C |
02352FSG: V200R013C02 and later versions 02352FSG-001: V200R020C10 and later versions 02352FSG-005: V200R021C10 and later versions (If V200R021C00SPC100 is used, install V200R021SPH010 or a later patch.) 02353GFC: V200R013C02 and later versions 02353GFC-001: V200R020C10 and later versions 02353GFC-003: V200R021C10 and later versions (If V200R021C00SPC100 is used, install V200R021SPH010 or a later patch.) NOTE:
V200R021C01 is not supported. Some models cannot be downgraded due to component upgrade. Therefore, you are advised to run the display system-software information command to check the software versions supported by the device before performing a downgrade. If the device does not support the display system-software information command, it can be downgraded. |
Appearance and Structure
1 |
Twenty-four 10GE SFP+ ports Applicable modules and cables:
|
2 |
Six 40GE/100GE QSFP28 optical ports Applicable modules and cables:
NOTE:
A QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module. For the S6730-H24X6C (part number: 02352FSG/02352FSG-001/02352FSG-005):
For the S6730-H24X6C (part number: 02353GFC/02353GFC-001/02353GFC-003), the license has been activated and QSFP28 ports on the switch work as 100GE ports. To change the rate of QSFP28 ports from 100GE to 40GE, run the undo assign port-speed 100GE command and restart the switch (undo assign port-type 100GE command in V200R020C00 and later versions). |
3 |
Ground screw NOTE:
It is used with a ground cable. |
4 |
SSD card slot NOTE:
This slot is reserved for future use. |
5 |
One console port |
6 |
One ETH management port |
7 |
One USB port |
8 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
9 |
Fan module slot 1 NOTE:
Applicable fan module: FAN-031A-B (Fan box(B,FAN panel side exhaust)) |
10 |
Fan module slot 2 NOTE:
Applicable fan module: FAN-031A-B (Fan box(B,FAN panel side exhaust)) |
11 |
Fan module slot 3 NOTE:
Applicable fan module: FAN-031A-B (Fan box(B,FAN panel side exhaust)) |
12 |
Fan module slot 4 NOTE:
Applicable fan module: FAN-031A-B (Fan box(B,FAN panel side exhaust)) |
13 |
Power module slot 1 NOTE:
Applicable power module:
|
14 |
Power module slot 2 NOTE:
Applicable power module:
|
Port Description
10GE SFP+ optical port
40GE/100GE QSFP28 optical port
Console port
ETH management port
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S6730-H24X6C has the same types of indicators as the S6730-H48X6C. For details, see Indicator Description.
Power Supply Configuration
The switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
Heat Dissipation
The S6730-H24X6C uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 4-192 lists technical specifications of the S6730-H24X6C.
Item |
Description |
---|---|
Memory (RAM) |
4 GB |
Flash |
2 GB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
62.27 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
N/A |
Power supply surge protection |
|
Dimensions (H x W x D) |
|
Weight (with packaging) |
8.9 kg (19.62 lb) |
Stack ports |
|
RTC |
Supported |
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
|
Maximum voltage range |
|
Maximum power consumption (100% throughput, full speed of fans) |
254 W |
Typical power consumption (30% of traffic load, tested according to ATIS standard) |
149 W |
Operating temperature |
-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0°C (32°F). The operating temperature of the switch is -5°C to 40°C (23°F to 104°F) when it uses QSFP-100G-ER4 optical module. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 65 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
|
Part number |
02352FSG 02352FSG-001 02352FSG-005 02353GFC 02353GFC-001 02353GFC-003 |