Version Mapping
Table 5-187 lists the mapping between the S6730-H24X6C chassis and software versions.
Table 5-187 Version mappingSeries
|
Model
|
Software Version
|
S6730-H
|
S6730-H24X6C
|
02352FSG: V200R013C02 and later versions
02352GFC: V200R013C02 and later versions
02352FSG-001: V200R020C10 and later versions
02352GFC-001: V200R020C10 and later versions
|
Appearance and Structure
Figure 5-82 S6730-H24X6C appearance![]()
1
|
Twenty-four 10GE SFP+ ports
Applicable modules and cables:
|
2
|
Six 40GE/100GE QSFP28 optical ports
Applicable modules and cables:
NOTE: A QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module.
For the S6730-H24X6C (part number: 02352FSG):
- By default, the license is not loaded on a switch.
- In V200R013C02, QSFP28 ports are 100GE ports.
- In V200R019C00 and later versions, QSFP28 ports are 40GE ports. To use the 100GE rate, you need to purchase and activate a license.
- After a switch is upgraded from V200R013C02 to V200R019C00 or a later version, QSFP28 ports are still 100GE ports. You can load a license to change the port rate.
- To change the rate of QSFP28 ports from 40 Gbit/s to 100 Gbit/s, load and activate this license, run the assign port-speed 100GE [ slot slot-id | all ] or assign port-type 100GE [ slot slot-id | all ] command, and restart the switch. To change the rate back to 40 Gbit/s, run the undo assign port-speed 100GE [ slot slot-id | all ] or undo assign port-type 100GE [ slot slot-id | all ] command and restart the switch.
In versions earlier than V200R020C00, the command format is assign port-speed 100GE [ slot slot-id | all ].
In V200R020C00 and later versions, the command format is assign port-type 100GE [ slot slot-id | all ].
For the S6730-H24X6C (part number: 02353GFC), the license has been activated and QSFP28 ports on the switch work as 100GE ports. To change the rate of QSFP28 ports from 100GE to 40GE, run the undo assign port-speed 100GE command and restart the switch (undo assign port-type 100GE command in V200R020C00 and later versions).
|
3
|
Ground screw
|
4
|
SSD card slot
NOTE: This slot is reserved for future use.
|
5
|
One console port
|
6
|
One ETH management port
|
7
|
One USB port
|
8
|
One PNP button
NOTICE: To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.
To reset the switch, press the button.
Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.
|
9
|
Fan module slot 1
|
10
|
Fan module slot 2
|
11
|
Fan module slot 3
|
12
|
Fan module slot 4
|
13
|
Power module slot 1
|
14
|
Power module slot 2
|
Port Description
10GE SFP+ optical port
A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s.
Table 5-188 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 5-188 Attributes of a 10GE SFP+ portAttribute
|
Description
|
Connector type
|
LC/PC
|
Optical port attributes
|
Depend on the optical module used
|
Standards compliance
|
IEEE802.3ae
|
Working mode
|
GE/10GE auto-sensing
|
40GE/100GE QSFP28 optical port
A 40GE/100GE QSFP28 optical port sends and receives service traffic at 40 Gbit/s or 100 Gbit/s.
Table 5-189 describes the attributes of a QSFP28 optical port.
Table 5-189 Attributes of a QSFP28 optical portAttribute
|
Description
|
Connector type
|
MPO/LC
|
Optical port attributes
|
Depend on the optical module used
|
Standards compliance
|
IEEE802.3ba
|
Console port
The console port is connected
to a console for on-site configuration. The port must use a
console cable. The console port is
used when a switch is powered on for the first time. For details about
the attributes of a console port, see
Table 5-190.
Table 5-190 Attributes of a console port
Attribute
|
Description
|
Connector type
|
RJ45
|
Standards compliance
|
RS-232
|
Working mode
|
Duplex Universal Asynchronous Receiver/Transmitter (UART)
|
Baud rate
|
9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200
bit/s
Default value: 9600 bit/s
|
ETH management port
You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. The port must use an
Ethernet cable. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port.
Table 5-191 describes the attributes of an ETH management port.
Table 5-191 Attributes of an ETH management portAttribute
|
Description
|
Connector type
|
RJ45
|
Standards compliance
|
IEEE802.3
|
Working Mode
|
10/100 Mbit/s auto-sensing
|
Maximum transmission distance
|
100 m
|
In V200R012C00 and later versions, you can log in to the switch that contains the ETH management port for the first time through the ETH port. For details, see "First Login to a Switch" in the
Configuration Guide - Basic Configuration. If you have logged in to the switch for the first time by pressing and holding the MODE button for 6 seconds or longer and saved the configuration, the default configuration on the ETH port will be cleared. In this case, you cannot log in to the switch for the first time through the ETH port. You are advised to log in to the switch for the first time through the ETH port.
USB port
The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S6730-H24X6C has the same types of indicators as the S6730-H48X6C. For details, see Indicator Description.
Power Supply Configuration
The S6730-H24X6C can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
Heat Dissipation
The S6730-H24X6C uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel. Fan modules support 3+1 backup.
![]()
This figure only shows the airflow direction and does not depict the actual device.
Technical Specifications
Table 5-192 lists technical specifications of the S6730-H24X6C.
Table 5-192 Technical specificationsItem
|
Description
|
Memory (RAM)
|
4 GB
|
Flash
|
2 GB in total. To view the available flash memory size, run the display version command.
|
Mean time between failures (MTBF)
|
62.27 years
|
Mean time to repair (MTTR)
|
2 hours
|
Availability
|
> 0.99999
|
Service port surge protection
|
N/A
|
Power supply surge protection
|
- Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode
- Using DC power modules: ±2 kV in differential mode, ±4 kV in common mode
|
Dimensions (H x W x D)
|
- Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)
- Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.4 in. x 17.6 in.)
|
Weight (with packaging)
|
8.9 kg (19.62 lb)
|
Stack ports
|
- Any 10GE SFP+ ports (a maximum of 16 physical ports)
- Any 40GE/100GE QSFP28 ports (a maximum of 6 physical ports)
|
RTC
|
Supported
|
RPS
|
Not supported
|
PoE
|
Not supported
|
Rated voltage range
|
- AC input: 100 V AC to 240 V AC, 50/60 Hz
- High-Voltage DC input: 240 V DC
- DC input: -48 V DC to -60 V DC
|
Maximum voltage range
|
- AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz
- High-Voltage DC input: 190 V DC to 290 V DC
- DC input: -38.4 V DC to -72 V DC
|
Maximum power consumption (100% throughput, full speed of fans)
|
254 W
|
Typical power consumption (30% of traffic load, tested according to ATIS standard)
|
149 W
|
Operating temperature
|
-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
The switch cannot be started when the ambient temperature is lower than 0°C (32°F).
The operating temperature of the switch is -5°C to 40°C (23°F to 104°F) when it uses QSFP-100G-ER4 optical module.
|
Storage temperature
|
-40°C to +70°C (-40°F to +158°F)
|
Noise under normal temperature (27°C, sound power)
|
< 65 dB(A)
|
Relative humidity
|
5% to 95%, noncondensing
|
Operating altitude
|
0-5000 m (0-16404 ft.)
|
Certification
|
- EMC certification
- Safety certification
- Manufacturing certification
|
Part number
|
- 02352FSG
- 02352FSG-001
- 02353GFC
- 02353GFC-001
|