Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Technical Specifications

Technical Specifications

Table 2-4 Technical specifications

Category

Item

Specifications

Physical specifications

Dimensions (H x W x D)

388.55 mm x 35.06 mm x 272.15 mm (15.30 in. x 1.38 in. x 10.71 in.)

Color

Silver white

Net weight

2.2 kg (4.85 lb)

Environmental specifications

Temperature

  • Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Class A3 compliant)
  • Storage temperature: -40°C to +65°C (-40°F to +149°F)
  • Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)
  • Temperature change rate < 20°C/h (36°F/h)
NOTE:
  • The compute node configured with E5-2643 v4 or E5-2637 v4 processors can work at a maximum temperature of 35°C (95°F). If the environment temperature is over 35°C (95°F) or one fan fails, the processor performance may deteriorate.
  • The compute node configured with E5-2667 v4 processors can work at the maximum temperature of 30°C (86°F). If the environment temperature is over 30°C (86°F) or one fan fails, the processor performance may deteriorate.

Temperature change rate

15 °C/h (27 °F/h)

Humidity

  • Operating humidity: 5% RH to 85% RH
  • Storage humidity: 5% RH to 95% RH
  • Long-term storage humidity: 30% RH to 69% RH
  • Humidity change rate < 20% RH/h

Altitude

At an altitude of 900 m (2952.72 ft), the highest operating temperature is 40°C (104°F).

When the device is used at an altitude of 900 m to 5000 m, the highest operating temperature decreases by 1°C (1.8°F) for every increase of 300 m (984.24 ft).

Corrosive air pollutant

  • Corrosion rate of the copper test piece < 300 Å/month (in compliance with the ANSI/ISA-71.04-2013 gaseous corrosion level G1)
  • Corrosion rate of the silver test piece < 200 Å/month

Particulate pollutant

  • The ISO14664-1 Class 8 requirements are met.

    It is recommended that a professional company monitor particulate pollutants in the equipment room.

  • There is no explosive, conductive, magnetic, or corrosive dust in the equipment room.

Input power supply specifications

Rated input voltage

12 V DC

Power consumption

Maximum power consumption

28 W