CX116 Pass-Through Module V100R001 User Guide 16

This document describes the CX116 gigabit Ethernet (GE) pass through module of the Tecal E9000 server (short for E9000) in terms of its features, installation, removal, and maintenance.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing the CX116

Installing the CX116

Scenarios

This topic describes a recommended process for installing a CX116 in the E9000 chassis. Get familiar with hardware devices before any operation.

Prerequisites

Tools

The following tools must be available before the installation:

  • Electrostatic discharge (ESD) gloves
  • Phillips screwdriver (PH3 is 8 mm or 0.31 in.)

Workflow

Figure 3-1 Installation process

Procedure

  1. Install the E9000 chassis.
  2. Determine the installation position.

    Determine the position for installing a CX116 in the chassis.
    Figure 3-2 Slot numbers

  3. Remove the filler panel.

    1. Use a Phillips screwdriver to loosen the two M3 captive screws on the filler panel. See step (1) in Figure 3-3.
      Figure 3-3 Removing the filler panel
    2. Raise the ejector levers on the CX116 completely. See step (2) in Figure 3-3.
    3. Pull the filler panel out of the chassis horizontally and lower the ejector levers of the filler panel. See step (3) and (4) in Figure 3-3.
    4. Store the removed filler panel properly for future use.

  4. Install the CX116.

    1. Raise the two ejector levers on the CX116 completely, and push the CX116 into the chassis horizontally. See steps (1) and (2) in Figure 3-4.
      Figure 3-4 Installing the CX116
    2. Lower the two ejector levers on the CX116 completely. See step (3) in Figure 3-4.
    3. Use a Phillips screwdriver to tighten the two M3 captive screws on the CX116. See step (4) in Figure 3-4.

  5. Determine the port for connecting a signal cable.

    Determine the port on the CX116 for connecting a signal cable.

    Figure 3-5 Port types and numbers
    NOTE:

    For details about the port numbers, see Figure 2-5.

  6. Connect a gigabit Ethernet (GE) cable.

    Figure 3-6 Connecting a GE cable

  7. Check the indicator status.

    For details about the indicators, see Table 2-2.