CX910 Switch Module V100R001C00 User Guide 22

This document describes the CX910 10GE switch module (CX910 for short) of the Tecal E9000 server in terms of its features, installation, removal, and configuration. This document applies to the CX910 whose GE/10GE switching planes use the software versions of 1.1.x.x.x, and 1.23-1.99.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Removing the CX910

Removing the CX910

Scenarios

Remove the CX910 from the E9000 chassis. Before the operation, become familiar with the hardware devices.

To replace a switch module, see section "Replacing a Switch Module" in the E9000 Server V100R001 User Guide.

Impact on the System

After the switch module is removed, all services running on the switch module stop.

Prerequisites

Tools

The following tools are available:

  • Protective gloves
  • Electrostatic discharge (ESD) gloves
  • Phillips screwdriver (PH2 is 6 mm or 0.25 in.)

Workflow

Figure 3-9 Removal process

Procedure

  1. Determine the CX910 to be removed.

    Figure 3-10 Slot numbers

  2. Determine the connection relationships between signal cables and ports on the CX910.

    Figure 3-11 Port types and numbers

    1

    BMC serial port

    2

    SYS serial port

    3

    GE electrical port(reserved)

    4

    10GE optical port

  3. (Optional) Remove a serial cable.

    Figure 3-12 Removing a serial cable
    NOTE:

    The BMC serial port, SYS serial port, are standard RJ-45 ports and are disconnected in the same way.

  4. Remove a 10GE optical fiber and optical module.

    1. Remove the optical fiber from the optical module. See (1) and (2) in Figure 3-13.
    2. Install the dust-proof cap for the optical module. See (3) in Figure 3-13.
      Figure 3-13 Removing an optical fiber
    3. Determine the optical module type and removal position based on site requirements.
    4. Remove the optical module horizontally from the optical port, as shown in Figure 3-14.
      Figure 3-14 Removing an optical module

  5. Remove the CX910.

    1. Use a Phillips screwdriver to loosen the two M3 captive screws. See (1) in Figure 3-15.
      Figure 3-15 Removing the switch module
    2. Raise the two ejector levers on the CX910 completely and pull the switch module horizontally out of the chassis. See (2) and (3) in Figure 3-15.
    3. Lower the ejector levers on the CX910. See (4) in Figure 3-15.
      NOTICE:

      An ESD bag holds only one switch module.

    4. Place the removed switch module into an ESD bag.

  6. Install a switch module filler panel.

    1. Raise the two handles on the switch module filler panel and push the filler panel horizontally into the chassis as far as it will go. See (1) in Figure 3-16.
      Figure 3-16 Installing a switch module filler panel
    2. Lower the two handles on the switch module filler panel. See (2) in Figure 3-16.
    3. Use a Phillips screwdriver to tighten the two M3 captive screws on the switch module filler panel. See (3) in Figure 3-16.