CX910 Switch Module V100R001C00 User Guide 22

This document describes the CX910 10GE switch module (CX910 for short) of the Tecal E9000 server in terms of its features, installation, removal, and configuration. This document applies to the CX910 whose GE/10GE switching planes use the software versions of 1.1.x.x.x, and 1.23-1.99.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking the Switching Plane

Checking the Switching Plane

Scenarios

Check the operating status of the 10GE switching plane of the CX910. Ensure that the service planes meet the basic requirements for data configuration.

Prerequisites

Software

PuTTY.exe is free software. You can download it from the Internet. The PuTTY used to log in over a serial port must be 0.60 or later.

Procedure

  1. Log in to the CLI of the 10GE switching plane.
  2. Run the following command on the 10GE switching plane CLI to check the current version of the 10GE switching plane:

    <Fabric> display version

    The command output is as follows:

    BoardName                : CX910                   
    CPLD Version             : 011                     
    PCB Version              : VER.C                   
    rcw Version              : 001                     
    backup rcw Version       : 001                     
    Bootrom Version          : 021                     
    Creation Time            : Sep 16 2013, 18:29:35 
    Backup Bootrom Version : 021                     
    Creation Time            : Sep 16 2013, 18:29:35 
    Switch Version           : 1.2.1.0.19              
    Creation Time            : Sep 23 2013, 10:28:41 
    Backup Switch Version    : 1.2.1.0.19 

    The value of PCB Version is the hardware version of the current plane. The value of Switch Version is the software version of the current plane.

  3. View the mapping of ports on the 10GE switching plane.

    <Fabric> display port-connection-relationships

    The command output is as follows:

    FABRIC PLANE 58 PORTS 
    XGigabitEthernet 0/0/1     :  SFI-1 
    XGigabitEthernet 0/0/2     :  SFI-2 
    XGigabitEthernet 0/0/3     :  SFI-3 
    XGigabitEthernet 0/0/4     :  SFI-4 
    XGigabitEthernet 0/0/5     :  SFI-5 
    XGigabitEthernet 0/0/6     :  SFI-6 
    XGigabitEthernet 0/0/7     :  SFI-7 
    XGigabitEthernet 0/0/8     :  SFI-8 
    XGigabitEthernet 0/0/9     :  SFI-9 
    XGigabitEthernet 0/0/10    :  SFI-10 
    XGigabitEthernet 0/0/11    :  SFI-11 
    XGigabitEthernet 0/0/12    :  SFI-12 
    XGigabitEthernet 0/0/13    :  SFI-13 
    XGigabitEthernet 0/0/14    :  SFI-14 
    XGigabitEthernet 0/0/15    :  SFI-15 
    XGigabitEthernet 0/0/16    :  SFI-16 
    XGigabitEthernet 0/0/17    :  Slot01 
    XGigabitEthernet 0/0/18    :  Slot01 
    XGigabitEthernet 0/0/19    :  Slot01 
    XGigabitEthernet 0/0/20    :  Slot02 
    XGigabitEthernet 0/0/21    :  Slot02 
    XGigabitEthernet 0/0/22    :  Slot02 
    XGigabitEthernet 0/0/23    :  Slot03 
    XGigabitEthernet 0/0/24    :  Slot03 
    XGigabitEthernet 0/0/25    :  Slot03 
    XGigabitEthernet 0/0/26    :  Slot04 
    XGigabitEthernet 0/0/27    :  Slot04 
    XGigabitEthernet 0/0/28    :  Slot04 
    XGigabitEthernet 0/0/29    :  Slot05 
    XGigabitEthernet 0/0/30    :  Slot05 
    XGigabitEthernet 0/0/31    :  Slot05 
    XGigabitEthernet 0/0/32    :  Slot06 
    XGigabitEthernet 0/0/33    :  Slot06 
    XGigabitEthernet 0/0/34    :  Slot06 
    XGigabitEthernet 0/0/35    :  Slot07 
    XGigabitEthernet 0/0/36    :  Slot07 
    XGigabitEthernet 0/0/37    :  Slot07 
    XGigabitEthernet 0/0/38    :  Slot08 
    XGigabitEthernet 0/0/39    :  Slot08 
    XGigabitEthernet 0/0/40    :  Slot08 
    XGigabitEthernet 0/0/41    :  Slot09 
    XGigabitEthernet 0/0/42    :  Slot09 
    XGigabitEthernet 0/0/43    :  Slot10 
    XGigabitEthernet 0/0/44    :  Slot10 
    XGigabitEthernet 0/0/45    :  Slot11 
    XGigabitEthernet 0/0/46    :  Slot11 
    XGigabitEthernet 0/0/47    :  Slot12 
    XGigabitEthernet 0/0/48    :  Slot12 
    XGigabitEthernet 0/0/49    :  Slot13 
    XGigabitEthernet 0/0/50    :  Slot13 
    XGigabitEthernet 0/0/51    :  Slot14 
    XGigabitEthernet 0/0/52    :  Slot14 
    XGigabitEthernet 0/0/53    :  Slot15 
    XGigabitEthernet 0/0/54    :  Slot15 
    XGigabitEthernet 0/0/55    :  Slot16 
    XGigabitEthernet 0/0/56    :  Slot16 
    XGigabitEthernet 0/0/57    :  Fabric Interconnection 
    XGigabitEthernet 0/0/58    :  Fabric Interconnection
    Table 4-8 Ports on the 10GE switching plane

    Port

    Description

    SFI-1 to SFI-16

    Ports 1 to 16 in the middle of the switch module panel

    Slot01 to slot16

    Ports connected to front slots 1 to 16 in the chassis

    Fabric Interconnection

    A port connected to the 10GE switching plane of the other switch module