Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Importing and Transferring Licenses (Only for the CX210 and CX912)

Importing and Transferring Licenses (Only for the CX210 and CX912)

The section describes how to import and transfer a POD license when replacing a CX210 or CX912.

Both the CX210 and CX912 switch modules have the MX210s. The CX210 or CX912 can be classified into the following spare part types based on the default number of activated ports on the MX210 and you need to perform different license operations on different types of spare parts:

  • Spare part with 24 ports:

    The MX210 of the earlier version has 24 activated ports by default. No POD license application form is available. This spare part is used to replace the 24-port switch module on the live network, but it will be replaced gradually.

  • Spare part with 20+4 ports:

    For this spare part, 20 ports are activated by default and a POD license application form is attached. This form can be used to activate another four ports. This spare part is used to replace the 24-port switch module on the live network.

    NOTE:

    The application form is in an envelope delivered with the switch module. The POD license code is in the 0533xxxx format and printed on the application form.

  • Spare part with 20 ports:

    The MX210 of the later version has 20 activated ports by default and is used to replace the switch modules with 20 ports on the live network.

Procedure

  1. Identify the type of the switch module to be replaced and the spare part type of the switch module.

    • If the switch module is not installed in the chassis:

      Identify the type of the switch module based on the part number. The part number consists of eight characters (digits or letters) and is in the 0305xxxx format. Take the CX210 as an example. If its part number is 03056183, apply for a switch module with 24 or 20+4 ports. If its part number is 03056859, apply for a switch module with 20 ports.

      NOTE:

      If the spare part package contains the printed POD license application form, the spare part is a switch module with 20+4 ports. If the spare part package does not contain the printed POD license application form, the spare part is a switch module with 24 ports.

      You can check the part number by using any of the following methods:

      • Check the label on the switch module packing case.
      • Check the delivery list.
      • Check the bar code (in the 210305xxxxyyyyyyyy format) on a switch module ejector lever. 0305xxxx is the part number.
    • If the switch module is installed in the chassis:

      Log in to the CLI to view port information. For details, see "Checking the FC Switching Plane" in the CXxxx Switch Module User Guide.

      • If ports 5 to 8 are in the "(No POD License) Disabled" state, the switch module has 20+4 or 20 ports.
        NOTE:

        If the spare part package contains the printed POD license application form, the spare part is a switch module with 20+4 ports. If the spare part package does not contain the printed POD license application form, the spare part is a switch module with 20 ports.

      • If ports 5 to 8 are not in the "(No POD License) Disabled" state, the switch module has 24 ports.

  2. Select the license operation based on the type of the switch module to be replaced and the spare part type of the switch module.

    Table 6-6 License operations based on the type of the switch module to be replaced and the spare part type of the switch module

    Type of the Switch Module to Be Replaced

    Spare Part Type of the Switch Module

    License Operation

    24 ports

    24 ports

    License operations are not required.

    20+4 ports

    NOTE:

    Before performing the license operation, ensure that you have applied for a POD license by referring to Applying for a License (Only for the CX210 and CX912).

    Import the POD license. For details, see "Importing a License Using Commands" or "Importing a License Using Web Tools" in the CXxxx Switch Module User Guide.

    20+4 ports (The POD license has been activated.)

    20 ports

    Transfer the POD license. For details, see "Transferring Licenses" in the CXxxx Switch Module User Guide.

    20 ports

    20 ports

    License operations are not required.

Translation