Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Replacing a Half-Width/Full-Width Compute Node

Replacing a Half-Width/Full-Width Compute Node

Workflow

Figure 6-5 Process

Procedure

  1. Determine the compute node to be replaced.

    Figure 6-6 show the slot numbers of half-width compute nodes.

    Figure 6-7 and Figure 6-8Figure 6-8 show the slot numbers of full-width compute nodes.
    Figure 6-6 Slot numbers of half-width compute nodes
    Figure 6-7 Slot numbers of the CH240, CH242, CH225 V3, CH226 V3, CH242 V3, CH242 V3 DDR4, CH225 V5, and CH242 V5 full-width compute nodes
    Figure 6-8 Slot numbers of the CH220, CH221, CH222, CH220 V3, CH222 V3, and CH221 V5 full-width compute nodes
    NOTE:
    • A maximum of 16 half-width compute nodes or eight full-width compute nodes can be installed in an E9000 chassis.
    • The compute nodes must be installed in slots from bottom to top.

  2. Power off the compute node.

    Before powering off the compute node, ensure that service data has been backed up.

    For details about how to power off a compute node, see the compute node user guide.

  3. Remove the compute node.

    1. Press the ejector release button(s) on the compute node. See (1) in Figure 6-9 and Figure 6-10.
      Figure 6-9 Removing a half-width compute node
      Figure 6-10 Removing a full-width compute node
    2. Completely open the ejector lever(s) on the compute node. See (2) in Figure 6-9 and Figure 6-10.
    3. Horizontally pull out the compute node from the chassis. See (3) in Figure 6-9 and Figure 6-10.
    4. Close the ejector lever(s) on the compute node. See (4) in Figure 6-9 and Figure 6-10.
    5. Place the removed compute node into an ESD bag.

      An ESD bag can hold only one compute node.

  4. Determine whether to replace the components in the compute node.

    • If yes, replace the faulty components. For details, see the CHxxx Compute Node User Guide.
    • If no, go to 5.

  5. Install a new compute node.

    • Install a half-width compute node.
      1. (Optional) Install a partition board.
        NOTE:

        You need to install a partition board between two half-width compute nodes. Perform this operation only when no partition board is installed between two half-width compute nodes.

        1. Tilt the partition board and insert it into the chassis. Align the partition board with the installation holes and then make the partition board upright. See (1) and (2) in Figure 6-11.
        2. Pull the partition board outward. See (3) and (4) in Figure 6-11.

          The partition board is properly installed when you hear a clicking sound.

          Figure 6-11 Installing a partition board
      2. Press the ejector release button on the half-width compute node. See (1) in Figure 6-12.
        Figure 6-12 Installing a half-width compute node
      3. Completely open the ejector lever on the half-width compute node. See (2) in Figure 6-12.
      4. Horizontally insert the half-width compute node into the chassis. See (3) in

        Figure 6-12.

      5. Close the ejector lever on the half-width compute node. See (4) in

        Figure 6-12.

    • Install a full-width compute node.
      1. (Optional) Remove the partition board.
        NOTE:

        Perform this operation only when there is a partition board in the slot where a full-width compute node is to be installed.

        1. Press and hold down the hole and push the partition board inwards. See (1) and (2) in Figure 6-13.
        2. Move the partition board rightwards and remove it. See (3) and (4) in

          Figure 6-13

        Figure 6-13 Removing the partition board
      2. Press the ejector release buttons on the full-width compute node. See (1) in Figure 6-14.
        Figure 6-14 Installing a full-width compute node
      3. Completely open the ejector levers on the full-width compute node. See (2) in

        Figure 6-14.

      4. Horizontally insert the full-width compute node into the chassis. See (3) in Figure 6-14.
      5. Close the ejector levers on the full-width compute node. See (4) in Figure 6-14.

  6. Power on the compute node.
  7. Check the HLY indicator status.

    If the HLY indicator is steady green, the compute node is operating properly.