E9000 Server V100R001 User Guide 24

This document describes the overview, functions, structure, installation, and configuration methods of the E9000.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing a Half-Width Compute Node

Installing a Half-Width Compute Node

During operations, wear protective gloves to prevent personal injury.

Workflow

Figure 3-26 Process

Procedure

  1. Unpack the packing case.

    1. Check whether the packing case and seals are in good condition.
      NOTE:

      If the packing case is damaged (for example, the packing case is wet or deformed, or the seal or pressure-sensitive tape is unsealed), fill in the Cargo Problem Feedback Form.

    2. Use a box cutter to cut the pressure-sensitive tape of the packing case.

      When using a box cutter to unpack a packing case, ensure that the knife edge is of a proper protrusion to avoid hurting hands or damaging the device in the packing case.

    3. Unpack the half-width compute node, as shown in Figure 3-27.
      Figure 3-27 Unpacking the half-width compute node
    4. Take out the half-width compute node in its ESD bag and place it on the ESD floor.

      Take a compute node out of its ESD bag only before you install it immediately.

      Figure 3-28 Proper operations
      Figure 3-29 Improper operations

  2. Determine the slot for installing the half-width compute node.

    Figure 3-30 Slot numbers of half-width compute nodes
    NOTE:
    • A maximum of 16 half-width compute nodes can be installed in an E9000 chassis.
    • Half-width compute nodes must be installed in slots from bottom to top. The slot sequence is as follows: slots 1, 9, 2, 10, 3, 11, 4, 12, 5, 13, 6, 14, 7, 15, 8, and 16

  3. Remove the filler panel.

    1. Press the ejector release button on the filler panel. See (1) in Figure 3-31.
      Figure 3-31 Removing the filler panel

    2. Completely open the ejector lever on the filler panel. See (2) in Figure 3-31.
    3. Pull out the filler panel from the chassis. See (3) in Figure 3-31.
    4. Close the ejector lever on the filler panel. See (4) in Figure 3-31.
    5. Place the removed filler panel in an accessory recycling bin.

  4. Install the compute node.

    1. (Optional) Install a partition board. Perform this operation only when no partition board is installed between two half-width compute node slots.
      1. Tilt the partition board and insert it into the chassis. Align the partition board with the mounting holes and then make the partition board upright. See (1) and (2) in Figure 3-32.
        Figure 3-32 Installing a partition board
      2. Pull the partition board outwards until it clicks into place. See (3) and (4) in Figure 3-32.
    2. Press the ejector release button on the half-width compute node. See (1) in Figure 3-33.
      Figure 3-33 Installing the half-width compute node
    3. Completely open the ejector lever on the half-width compute node. See (2) in Figure 3-33.
    4. Horizontally insert the half-width compute node into the chassis. See (3) in Figure 3-33.
    5. Close the ejector lever on the half-width compute node. See (4) in Figure 3-33.