MM910 Management Module V100R001 User Guide 24

This document provides the product description, installation and configuration methods, and common operations of the E9000 server chassis management module MM910.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Indicators

Indicators

You can observe the indicators to determine the current status of the MM910. Table 2-3 describes the indicators on the MM910 panel.

Table 2-3 Indicators

Indicator

Function

Color

Description

PWR

Power indicator

Green

  • Off: The MM910 is not powered on.
  • Blinking green: The MM910 is being powered on.
  • Steady green: The MM910 is powered on.

HLY

Health status indicator

Red or green

  • Off: The MM910 is not powered on.
  • Steady green: All components in the chassis are operating properly.
  • Blinking red (at 1 Hz): A major alarm is generated for a component in the chassis. The HLY indicators on the active and standby MM910s are blinking red.
  • Blinking red (at 4 Hz): A critical alarm is generated for a component in the chassis. The HLY indicators on the active and standby MM910s are blinking red.
  • Blinking red (at 5 Hz): The MM910 is not firmly seated in the slot.
NOTE:

It is difficult to identify the difference between blinking frequencies of 4 Hz and 5 Hz. If the indicator is blinking red quickly, check whether the device has been installed properly and then check whether a critical alarm has been generated.

ACT

Active/Standby indicator

Green

  • Off: The MM910 is in the standby state.
  • Steady green: The MM910 is in the active state.

Data transmission status indicator

Data transmission status indicator

Orange

  • Off: No data is being transmitted over the port.
  • Blinking orange: Data is being transmitted over the port.

Connection status indicator

Connection status indicator

Green

  • Off: The port is disconnected.
  • Steady green: The port is connected.
Translation
Download
Updated: 2019-04-10

Document ID: EDOC1000015900

Views: 78866

Downloads: 5195

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next