MM910 Management Module V100R001 User Guide 24

This document provides the product description, installation and configuration methods, and common operations of the E9000 server chassis management module MM910.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Information Collection

Information Collection

When both the master and slave chassis are installed, the slave chassis does not support information collection.

GUI

Function

On the Information Collection page, you can collect operating information of the MM910, compute nodes, and switch modules and save the information on the client.

Figure 7-36 shows the information collection relationships and Table 7-108 describes the contents that can be collected.

Figure 7-36 Information collection relationships

Table 7-108 Information collection description

Collection Module

Collected Content

Chassis

Collects the same files and content as one-click full-collection of the collection source MM. For specific files, see 1, 2, 3, 4, and 5 in Table 7-109.

NOTE:

Full collection of the chassis collects all switch module logs and may take up to 30 minutes.

Supports advanced configuration for collecting information of specified switch module or compute node slots.

MM

One-click full collection: Performs one-click quick information collection and one-click compute node and switch module information collection. For specific files, see 1, 2, 3, 4, and 5 in Table 7-109.

One-click quick collection: Collects the installation status of compute nodes, switch modules, fans, and power supply units (PSUs) and collects system event logs of the MM910. For specific files, see 1 and 2 in Table 7-109.

Log export:

  • Collects operation logs of the MM910.
  • Collects system event logs of the MM910, fans, and PSUs.

. For specific files, see 1 in Table 7-109.

Slot1 - Slot32

Log export: Collects system event logs and operation logs of compute nodes. For specific files, see 4 in Table 7-109.

Black box: Saves the system status information and debugging information before the system is reset. For specific files, see 6 in Table 7-109.

Serial port recording: Records the operation information of compute node serial ports. For specific files, see 7 in Table 7-109.

Swi1 - Swi4

Log export: Collects system event logs and operation logs of switch modules. For specific files, see 5 in Table 7-109.

NOTE:
  • The sizes of black box and serial port recording files are generally large. Therefore, the system automatically deletes the files collected for a previous compute node before collecting these files for the next compute node.
  • If the compute node iBMC version is earlier than 2.0, you need to log in to the iBMC to collect logs.
  • When the switching plane log of the switch module exceeds 15 MB or the BMC log of the switch module exceeds 6 MB, the switch plane log and BMC log collected by using the one-click full collection function of the MM are empty.

File Collection Description

Table 7-109 File collection description

No.

Level 2 Subdirectory

File Name

Description

1

smm\infoCollect\traplog

snmptrap.log

Log recording the sending of trap messages.

snmptrap.log .*.gz

Compressed trap message logs. A maximum of five compressed packages are allowed.

smm\infoCollect\log

user.log

User operation logs.

sel.log

MM910 SELs.

smm\infoCollect\log\sel

smmsel*.gz

Compressed SELs. A maximum of 10 compressed packages are supported.

smm\infoCollect\log\user

user.log.*.gz

Compressed operation logs. A maximum of 10 compressed packages are supported.

fanspeedlog

fanspeedlog.txt

Fan speed log.

fanspeedlog_bak*.txt

Backup of the fan speed logs. A maximum of four log backups are allowed.

LswShow

lswshow_buffercount_ge*

Buffer use information of a specific port. ge* indicates the port name, which can be ge0 to ge25.

lswshow_buffercount_xe0

Buffer use information of port xe0.

lswshow_bufferlimit_ge*

Buffer limit information of a specific port. ge* indicates the port name, which can be ge0 to ge25.

lswshow_bufferlimit_xe0

Buffer limit information of port xe0.

lswshow_counter_ge*

Statistics of a specific port. ge* indicates the port name, which can be ge0 to ge25.

lswshow_counter_xe0

Statistics of port xe0.

lswshow_dfxinfo

Alarm information detected by DFX.

lswshow_egressinfo

Isolation information of all ports.

lswshow_macinfo

MAC address information.

lswshow_parityinfo

Memory bit error information.

lswshow_phyinfo

PHY information.

lswshow_phyreginfo_ge*

PHY register information of a specific port. ge* indicates the port name, which can be ge0 to ge25.

lswshow_phyreginfo_xe0

PHY register information of port xe0.

lswshow_portinfo_ge*

Information about a specific port. ge* indicates the port name, which can be ge0 to ge25.

lswshow_portinfo_xe0

Information about xe0.

lswshow_portmap

Port connection relationships.

lswshow_portparam_ge*

Transmitter emphasis and receiver equalization information of a specific port. ge* indicates the port name, which can be ge0 to ge25.

lswshow_portparam_xe0

Transmitter emphasis and receiver equalization information of port xe0.

lswshow_portstatus

Port status.

lswshow_pvidinfo

All port PVLAN information.

lswshow_rdbgcinfo

RDBGC information.

lswshow_tdbgcinfo

TDBGC information.

lswshow_vlanfilter_ge*

VLAN filter information of a specific port. ge* indicates the port name, which can be ge0 to ge25.

lswshow_vlanfilter_xe0

VLAN filter information of port xe0.

lswshow_vlaninfo

All VLAN information.

smm\infoCollect\sol_online

solr_switch_N.log

Interaction information logged over SOL when the easyLink configuration was delivered online.

NOTE:

N is the switch module or pass-through module slot number and ranges from 1 to 4.

solr_switch_N.log.*.gz

Compressed logs of the interaction information recorded over SOL when the easyLink configuration was delivered online. A maximum of four compressed packages are supported.

NOTE:

N is the switch module or pass-through module slot number and ranges from 1 to 4.

solw_switch_N.log

Commands logged over SOL when the easyLink configuration was delivered online.

NOTE:

N is the switch module or pass-through module slot number and ranges from 1 to 4.

solw_switch_N.log.*.gz

Compressed logs of the commands recorded over SOL when the easyLink configuration was delivered online. A maximum of four compressed packages are supported.

NOTE:

N is the switch module or pass-through module slot number and ranges from 1 to 4.

smm\infoCollect\abnormallog

abnormal_schedule.log

Profiles failed to be loaded during stateless computing and easyLink configuration.

abnormal_schedule.log.*.gz

Compressed package of the profiles failed to be loaded during stateless computing and easyLink configuration. A maximum of two compressed packages are supported.

smm\infoCollect\vpm

scheduleapply.log

Content of the profile delivered in stateless computing.

scheduleapply.log.*.gz

Compressed package of the stateless computing profiles delivered. A maximum of five compressed packages are supported.

smm\infoCollect\ldaplog

ldaplogin.txt

LDAP user login log information.

ldaplogin.txt.*.gz

Compressed LDAP user login logs. A maximum of five compressed packages are supported.

2

-

NOTE:

Applicable to software versions 5.57 or later.

fanspeedpolicy.txt

Fan speed adjustment policy.

power_shelf.csv

Historical chassis power consumption.

pemfaultreason.txt

Power alarm information.

summaryinfo.txt

Basic information about the chassis.

-

NOTE:

Applicable to software versions 3.00 to 5.57.

IT11SMMA_021RMU10EC000566_all_20150302

Compute node descriptions and serial numbers, and one-click collection time.

SMM_collectdata_file

Logs.

Smmget_Blade_Realtimepower&powercapping&powerreference&resetreason&diskboardpresence&systemInformation

Real-time power consumption, power cap value, power reference value, reset reason, disk expansion drawer installation status, host information on the service side, and system properties about compute nodes.

Smmget_-d_AllVersion

Software and hardware version information about all installed parts.

Smmget_Fan&PS_-d_current

Fan and PSU information detected by sensors.

Smmget_Fan&PS_Power_Fanspeed_Fru

Rated power, real-time power, and FRU information of PSUs, and speed and FRU information of fan modules.

Smmget_Lswfailed_-d_current

LAN switch failure status.

Smmget_Node&SWI&SMM&FAN&PS_Presence&Health&Hotswapstate

Presence, health, and hot swap status of all parts.

smmget_Shelf_Powerinfo&pemtype&fanspeed&fanframetype&fancontrolmode&powercappingenable

Real-time power, power capping enablement status, power cap value, PSU type, PSU rated power, fan speed, fan module type, and fan control mode of the system.

Smmget_Smm&Fan&Ps&Blade&Swi_BMCSel

System event logs (SELs) of all parts.

Smmget_Smm_Cpld_Fpga

CPLD and FPGA data.

Smmget_Smm_outportmode&poweroninterval&InletTemp&FlashRate&MemRate&smalert

Compute node power-on interval, management module management network port out mode, temperature, memory, flash memory usage rate, and power failure status.

Smmget_Smm_SensorInfo

Sensor values of the management module.

smm

NOTE:

Applicable to software versions 5.57 or later.

cpld_pfga.log

CPLD and FPGA information.

sel.csv

MM910 system event logs.

othersmm

one_touch_info_fast.tar.gz

Standby MM910 information collected in one-click mode.

smm\infoCollect

.bash_history

Historical commands executed by the root user.

access_log

Web-based access logs.

dmesg

System run logs.

dmesg.old

System run logs.

error_log

Web error logs.

messages

System run logs.

ntp.conf

NTP configuration file.

runParam.log

Management module running information, such as network configuration, processes, memory, hard disks, and key file permissions.

secure

System security logs.

SMM.CFG

IPMI process configuration information.

smmnetip.cfg

Network IP address configuration file.

snmpd.log

snmpd run logs.

syslog.log

System logs.

tftp-hpa

TFTP configuration file.

web_debug.CFG

Web debugging logs.

smm\infoCollect\log

clphistory

Historical commands executed by users.

loginfail.log

Login failure logs.

pme.log

Platform Management Engine (PME) framework logs.

fail.log

Command execution failure logs.

smmlog.txt

Management module debugging logs.

sys_event.log

Upgrade logs.

webfail.log

NOTE:

Applicable to software versions 5.57 or later.

WebUI login error logs.

smm\infoCollect\log\apache

-

Apache logs.

smm\infoCollect\log\clplog

clphistory.*.gz

Compressed CLP logs. A maximum of 10 compressed packages are supported.

smm\infoCollect\log\fail

fail.log.*.gz

Compressed failure logs. A maximum of 10 compressed packages are supported.

smm\infoCollect\log\kvmserver

kvmserver.log

KVM server logs.

smm\infoCollect\log\loginfail

NOTE:

Applicable to software versions 5.57 or later.

loginfail.log.*.gz

Compressed login failure logs. A maximum of five compressed packages are supported.

smm\infoCollect\log\redfish

redfish.log

REDFISH logs.

smm\infoCollect\log\webfail

NOTE:

Applicable to software versions 5.57 or later.

webfail.log.*.gz

Compressed webfail.log files. A maximum of two compressed packages are supported.

3

lsw

lsw_collect_data.txt

Management module LSW chip information.

swiN_fru1

NOTE:

Applicable to software versions 6.00 or later.

*.zip

Switch module N Base plane information collected in one-click mode.

NOTE:
  • N is the switch module or pass-through module slot number and ranges from 1 to 4.
  • If this file exceeds 15 MB, the information collected by using the one-click full collection function of the MM is empty.

swiN_fru2

NOTE:

Applicable to software versions 6.00 or later.

*.zip

Switch module N Fabric plane information collected in one-click mode.

NOTE:
  • N is the switch module or pass-through module slot number and ranges from 1 to 4.
  • If this file exceeds 15 MB, the information collected by using the one-click full collection function of the MM is empty.

4

bladeN

*.tar.gz

Compute node N information collected in one-click mode.

NOTE:

N is the compute node slot number and ranges from 1 to 32.

5

swiN

*.tar.gz

Switch module N information collected in one-click mode.

NOTE:
  • N is the switch module or pass-through module slot number and ranges from 1 to 4.
  • If this file exceeds 6 MB, the information collected by using the one-click full collection function of the MM is empty.
  • For details about one-click information collection of switch/pass-through module CX910, CX911, CX912, CX913, CX310, CX311, CX312, CX110, CX611, CX111, CX915, CX210, CX116, and CX317, see E9000 Server V100R001 iMana 200 User Guide.
  • For details about one-click information collection of switch/pass-through module CX220, CX318, CX320, CX610, CX710, CX712, and CX920, see E9000 Server V100R001 iBMC User Guide.

6

-

blackbox.dat

Black box.

7

-

systemcom.dat

Serial port voice recording.

Translation