This document provides the product description, installation and configuration methods, and common operations of the E9000 server chassis management module MM910.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing an MM910

Installing an MM910

Scenarios

Install an MM910 in an E9000 chassis.

Impact on the System

This operation has no adverse impact on the system.

Prerequisites

Conditions

The chassis has been installed.

Tools

  • ESD gloves
  • Phillips screwdriver (PH3 is 8 mm or 0.31 in.)

Process

Figure 3-1 shows the process for installing an MM910.

Figure 3-1 Installation process

Procedure

  1. Determine the installation position of the MM910.

    Figure 3-2 shows the slots for installing the MM910s.

    Figure 3-2 Slot numbers

  2. Remove the filler panel.

    1. Use a Phillips screwdriver to loosen the M3 captive screw on the MM910 filler panel. See (1) in Figure 3-3.
      Figure 3-3 Removing the filler panel

    2. Pull out the filler panel from the chassis slot horizontally. See (2) in Figure 3-3.
    3. Store the removed filler panel properly for future use.

  3. Install the MM910.

    1. Raise the MM910 ejector lever. See (1) in Figure 3-4.
      Figure 3-4 Installing the MM910

    2. Insert the MM910 horizontally into the chassis. See (2) in Figure 3-4.
    3. Lower the MM910 ejector lever. See (3) in Figure 3-4.
    4. Use a Phillips screwdriver to tighten the M3 captive screw on the MM910. See (4) in Figure 3-4.

  4. Check the status of the indicators on the MM910 after the MM910 is powered on.

    If the power (PWR) indicator and health (HLY) indicator are both steady green, the MM910 is powered on and all components in the chassis are operating properly.

    For details about the indicators, see Indicators.

  5. Connect a network cable to the network port of the MM910 based on the network plan.

    For details about the ports of the MM910, see Ports.