MM910 Management Module V100R001 User Guide 24

This document provides the product description, installation and configuration methods, and common operations of the E9000 server chassis management module MM910.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm Settings

Alarm Settings

Screenshot

Function

The Alarm Settings page allows you to configure whether to enable the chassis component removal alarms (for removal of a compute node, switch or pass-through module, management module, PSU, or fan module), management module heartbeat loss alarm, and management module switchover alarm. Table 7-77 describes the parameters.

Table 7-77 Parameter description

Parameter

Description

Insertion/Removal Alarm Settings

  • ON: An alarm is generated when a component is removed but not when a component is inserted.
  • OFF: No alarm is generated when a component is removed.

MM HA Alarm Settings

  • Heartbeat lost (minor alarm)
    • ON: An alarm is generated when heartbeats between the active and standby management modules are lost.
    • OFF: No alarm is generated when heartbeats between the active and standby management modules are lost.
  • MM switchover (information event)
    • ON: When an active/standby switchover occurs, an SNMP trap is sent. An email is also sent if SMTP is enabled with Alarm Severity set to All.
    • OFF: When an active/standby switchover occurs, no SNMP trap or email is sent.