E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Slot: CPU Not Detected (Major, CPU)

Slot: CPU Not Detected (Major, CPU)

Description

Alarm message:

Failed to start the system. CPU arg1 was not detected. 

This alarm is generated when the system failed to start and the specified CPU was not detected.

Alarm object:

CPU

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x00000073

Major

Yes

Parameters

Name

Meaning

arg1

Slot number of the CPU.

Impact on the System

The system cannot start.

Possible Causes

The CPU is not installed.

Procedure

  1. Power off the compute node and remove it from the chassis. Check whether the CPU is installed properly.

    You can power off the compute node using either of the following methods:
    • On the HMM CLI, run the smmset -l bladeN -d powerstate -v poweroff command.
    • On the HMM WebUI, choose PSUs & Fans > PSU Management > Power Control, and click the power control button to power off the compute node.
    • If yes, go to 2.
    • If no, go to 3.

  2. Check whether the CPU is installed properly.

    • If yes, go to 4.
    • If no, go to 6.

  3. Install the CPU. Then, power on the server and check whether the alarm is cleared.

    • If yes, go to 5.
    • If no, go to 4.

  4. Switch the CPU with a functioning CPU in the same chassis. Then, power on the server and check whether the alarm is cleared.

    • If yes, go to 5.
    • If no, go to 6.

  5. Check whether the system can start normally.

    • If yes, no further action is required.
    • If no, go to 6.

  6. Replace the mainboard. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 7.

  7. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  8. Contact Huawei technical support.