Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Slot: Overtemperature (Minor, Outlet Temp/Outlet TempN)

Slot: Overtemperature (Minor, Outlet Temp/Outlet TempN)

Description

Alarm message:

Temperature above minor threshold

This alarm is generated when the air inlet temperature exceeds the overtemperature minor threshold.

This alarm is generated by the following sensors:

  • Outlet Temp
  • Outlet TempN

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0147FF01

Minor

Yes

Parameters

Name

Meaning

N

Slot number of the sensor.

Impact on the System

Overheating affects component performance and server operations.

Possible Causes

  • The ambient temperature exceeds the normal range.
  • The air inlet or outlet is blocked.
  • Idle slots or spaces are not installed with filler panels.
  • The mainboard is faulty.

Procedure

  1. Check whether the equipment room temperature exceeds the normal range.

    • If yes, go to 2.
    • If no, go to 3.

  2. Reduce the equipment room temperature to the normal range. After 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Check whether the server air inlet or outlet is blocked.

    • If yes, go to 4.
    • If no, go to 5.

  4. Clear the blockage. After 5 minutes, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. Check whether there are empty slots in the server.

    • If yes, go to 7.
    • If no, go to 6.

  6. Install filler panels in empty slots. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 7.

  7. Replace the mainboard. Then, check whether the alarm is cleared.

    For details, see the server user guide.

    • If yes, no further action is required.
    • If no, go to 8.

  8. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  9. Contact Huawei technical support.