E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Slot: Overvoltage (Major, PCIE SWB Vcore)

Slot: Overvoltage (Major, PCIE SWB Vcore)

Description

Alarm message:

Voltage above upper major threshold

or

The arg1 PCIe switch arg2 VDD voltage (arg3 V)  exceeds the overvoltage threshold (arg4 V).

This alarm is generated when the VDD voltage of the PCIe switch chip exceeds the overvoltage threshold.

This alarm is generated by the following sensor:

PCIE SWB Vcore

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0149FF02

Major

Yes

Parameters

Name

Meaning

arg1

Component where the PCIe switch is located. For example, mainboard or HDD backplane N.

arg2

Slot number of the PCIe switch.

arg3

Current reading of the sensor.

arg4

Alarm threshold.

Impact on the System

The abnormal PCIe card voltage may cause the system or related services to break down.

Possible Causes

The PCIe card power supply is faulty

Procedure

  1. Power off the compute node and remove it from the chassis.

    You can power off the compute node using either of the following methods:
    • On the HMM CLI, run the smmset -l bladeN -d powerstate -v poweroff command.
    • On the HMM WebUI, choose PSUs & Fans > PSU Management > Power Control, and click the power control button to power off the compute node.

  2. Replace the PCIe card. Then check whether the alarm is cleared

    For details about how to replace the PCIe card, see the server user guide.
    • If yes, no further action is required.
    • If no, go to 3.

  3. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  4. Contact Huawei technical support.