E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Swi: Overvoltage (Major, Mezz SYS 1V/Mezz SYS 1.5V/Mezz SYS 1.8V/Mezz SYS 2.5V/Mezz SYS 3.3V/Mezz SYS 12V/Mezz STBY 3.3V)

Swi: Overvoltage (Major, Mezz SYS 1V/Mezz SYS 1.5V/Mezz SYS 1.8V/Mezz SYS 2.5V/Mezz SYS 3.3V/Mezz SYS 12V/Mezz STBY 3.3V)

Description

Alarm message:

Voltage above upper major threshold

or

Swtich mezzanine card arg1 voltage (arg2 V) at arg3 detection point exceeds the overvoltage threshold (arg4 V).

This alarm is generated when the voltage of the mezzanine card detection point exceeds the overvoltage threshold.

This alarm is generated by the following sensors:

  • Mezz SYS 1V
  • Mezz SYS 1.5V
  • Mezz SYS 1.8V
  • Mezz SYS 2.5V
  • Mezz SYS 3.3V
  • Mezz SYS 12V
  • Mezz STBY 3.3V

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0149FF02

Major

Yes

Parameters

Name

Meaning

arg1

Slot number of the mezzanine card.

arg2

Current reading of the sensor.

arg3

Voltage detection point.

arg4

Alarm threshold.

Impact on the System

When devices work with a upper voltage, the component performance deteriorates, the device service life shortens, which causes system breakdown.

Possible Causes

The mezzanine card in the switch module is faulty.

Procedure

  1. Back up service data of the mezzanine card, switch over services to the standby network.
  2. Replace the mezzanine card. Then, check whether the alarm is cleared.

    For details about how to replace the switch module, see the E9000 Server User Guide..

    • If yes, no further action is required.
    • If no, go to 3.

  3. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  4. Contact Huawei technical support.