E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Slot: Power Capping Failed (Minor, PwrCap Status)

Slot: Power Capping Failed (Minor, PwrCap Status)

Description

Alarm message:

Power capping failed.

This alarm is generated when a sensor detects that the power capping value of the compute node is lower than the power reference value.

This alarm is generated by the following sensor:

PwrCap Status

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0441FF12

Minor

Yes

Impact on the System

The Compute Node cannot operate properly.

Possible Causes

  • The number of Compute Node or other components increases.
  • The power consumption of other components increases.

Procedure

  1. On the HMM Web, choose PSUs&Fans > Power Management> Power Capping Settings.
  2. Click Edit, then check whether the power cap value of each compute node with power capping is in the valid range.

    • If yes, go to 4.
    • If no, go to 3.

  3. Set a valid chassis power cap value and click Save. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 4.

  4. Click Cancel and check whether a CH242 compute node exists.

    • If yes, go to 5.
    • If no, go to 6.

  5. Disable chassis power capping. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

  6. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  7. Contact Huawei technical support.
Translation