E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MM: Insufficient Power Supply (Major, Low power)

MM: Insufficient Power Supply (Major, Low power)

Description

Alarm message:

Insufficient power supply to the chassis

This alarm is generated when the real-time power consumption of the entire chassis is greater than the sum of PSU power ratings.

This alarm is generated by the following sensor:

Low power

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0742FF08

Major

Yes

Impact on the System

Power supply to the entire chassis is insufficient. As a result, compute nodes do not work properly, which affects service running.

Possible Causes

Power supply to the entire chassis is insufficient.

Procedure

  1. Check whether the CPLD version of the management module version information is earlier than 105.

    • If yes, go to 2.
    • If no, go to 3.

  2. Upgrade the CPLD version to 105 or later for the active and standby management modules. For details, see the upgrade guide. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Check whether any PSU alarm exists.

    • If yes, go to 4.
    • If no, go to 5.

  4. Handle the PSU alarm by referring to the alarm handling suggestion. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. Check whether the PSUs meet the power consumption requirements of the entire chassis.

    • If yes, go to 6.
    • If no, go to 7.

  6. If the PSUs are not fully configured, install more PSUs. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 7.

  7. On the HMM WebUI, choose System Management > Information Collection, and collect logs.