Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Slot: Server Powered Off (Major, PwrOk Sig. Drop)

Slot: Server Powered Off (Major, PwrOk Sig. Drop)

Description

Alarm message:

Power supply failure

or

The [arg1] power arg2 failure results abnormal power-off.

This alarm is generated when a voltage sag or an unexpected power failure occurs on the mainboard.

This alarm is generated by the following sensor:

PwrOk Sig. Drop

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0801FFFF

Major

Yes

Parameters

Name

Meaning

arg1

Serial number of the power supply, for example, LPM1.

arg2

Power supply subsystem name. For example, STBY_5V0 or STBY_1V8_PCH.

Impact on the System

When a voltage sag occurs, the power cannot be properly supplied to the system, or the server powers off, which interrupts services.

Possible Causes

  • The power supplies in the equipment room are sufficient for server operation.
  • The compute node is faulty.

Procedure

  1. Check whether the PSUs meet power requirement of the entire chassis.

    • If yes, go to 4.
    • If no, go to 2.

  2. Check whether the PSUs are fully configured.

    • If yes, go to 6.
    • If no, go to 3.

  3. Install more PSUs. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 4.

  4. Reseat the compute node. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. Replace the mainboard. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

  6. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  7. Contact Huawei technical support.