E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Slot: Memory Configuration Error (Critical, DIMMN)

Slot: Memory Configuration Error (Critical, DIMMN)

Description

Alarm message:

Configuration error, dimm is arg1 

or

arg1 configuration error or training failed.

This alarm is generated when a DIMM installation error or fault is detected during the BIOS startup process.

This alarm is generated by the following sensors:

DIMMN

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0C07FFFF

Critical

Yes

Parameters

Name

Meaning

N, arg1

  • DIMM silkscreen, for example, DIMM020 (A) or DIMM010 (B)
  • CPU socket number and channel number.

Impact on the System

If a configuration error occurs in the first DIMM slot for a CPU, the system cannot start. If a configuration error occurs in other DIMM slots, the system can start but the other DIMMs are not available.

Possible Causes

  • The DIMM is not installed in the correct slot.
  • The DIMM is faulty.
  • The mainboard is faulty.

Procedure

  1. Power off the server and check whether the DIMM installation positions are correct.

    For details about DIMM installation rules, see the server user guide.

    • If yes, go to 3.
    • If no, go to 2.

  2. Install the DIMMs in correct positions by referring to DIMM installation rules. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Check whether alarms are generated for multiple DIMMs of the same channel.

    • If yes, go to 4.
    • If no, go to 5.

  4. Switch the DIMM with a functioning DIMM in the same chassis. Then, check whether the alarm is still generated for this DIMM.

    • If yes, go to 5.
    • If no, go to 6.

  5. Replace the DIMM. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 7.

  6. Replace the mainboard. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 7.

  7. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  8. Contact Huawei technical support.