E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Slot: LOM MCE/AER Error (Critical, Mainboard)

Slot: LOM MCE/AER Error (Critical, Mainboard)

Description

Alarm message:

The LOM arg1 triggered an uncorrectable error,arg2.

This alarm is generated when an uncorrectable error is detected on the LOM.

Alarm object: mainboard

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x100000B1

Critical

Yes

Parameters

Name

Meaning

arg1

Serial number of the LOM.

arg2

Error code of the alarm.

Impact on the System

The NIC services are affected.

Possible Causes

The mainboard is faulty.

Procedure

  1. Replace the mainboard. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 2.

  2. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  3. Contact Huawei technical support.