Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MM: Config Error (Major, XCU mode match)

MM: Config Error (Major, XCU mode match)

Description

Alarm message:

c

This alarm is generated when the Fibre Channel (FC) or Fibre Channel over Ethernet (FCoE) configurations of the switch Module are different.

This alarm is generated by the following sensor:

XCU mode match

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x1B01FFFF

Major

Yes

Impact on the System

The FC or FCoE of the switch Module is not available and services cannot operate properly.

Possible Causes

  • Two switch Modules with different FC or FCoE configurations are installed in slots 2X and 3X.
  • Two switch Modules with different FC or FCoE configurations are installed in slots 1E and 4E.

Procedure

  1. Check whether the switch modules in slots 2X and 3X are the same.

    • If yes, go to 3.
    • If no, go to 2.

  2. Replace a switch module so that the two switch modules are the same. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Check whether the switch modules in slots 1E and 4E are the same.

    • If yes, go to 5.
    • If no, go to 4.

  4. Replace a switch module so that the two switch modules are the same. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  6. Contact Huawei technical support.
Translation