E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Swi: Power Supply to Base Plane Abnormal (Major, Mngmnt Health)

Swi: Power Supply to Base Plane Abnormal (Major, Mngmnt Health)

Description

Alarm message:

Power supply to arg1 failed or timed out. 

This alarm is generated when the Base plane is powered off exceptionally or the power-on of the Base plane timed out.

This alarm is generated by the following sensor:

Mngmnt Health

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x1D00002B

Major

Yes

Parameters

Name

Meaning

arg1

Name of the alarmed plane, for example, Base Plane.

Impact on the System

The Base plane is unavailable.

Possible Causes

The mainboard is faulty.

Procedure

  1. Back up service data of the switch module and switch over services to the standby network.
  2. Reseat the switch module. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Replace the switch module. Then, check whether the alarm is cleared.

    For details about how to replace the switch module, see the E9000 Server User Guide..

    • If yes, no further action is required.
    • If no, go to 4.

  4. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  5. Contact Huawei technical support.