E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Swi: Management LSW Chip Fault (Major, LSW Status)

Swi: Management LSW Chip Fault (Major, LSW Status)

Description

Alarm message:

Fault status

or

The management LSW chip on the iBMC of the switch module is faulty.

This alarm is generated when the management LSW chip on the iBMC or iMana 200 of the switch module is faulty.

This alarm is generated by the following sensor:

LSW Status

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2100FFFF

Major

Yes

Impact on the System

The switch module configuration cannot be synchronized to the MM, and users cannot log in to the iBMC of the switch module using SSH or SOL.

Possible Causes

The switch module is faulty.

Procedure

  1. Log in to the Base plane and Fabric plane respectively through the serial port, run the display current to query the configuration, and back up the configuration.
  2. Back up the services of the switch module.
  3. Reseat the switch module and then check whether the alarm is cleared..

    • If yes, no further action is required.
    • If no, go to 4.

  4. Replace the switch module. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  6. Contact Huawei technical support.