No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Swi: Failed to Read PIC Card Voltage (Minor, Mngmnt Health)

Swi: Failed to Read PIC Card Voltage (Minor, Mngmnt Health)

Description

Alarm message:

Sensor access degraded or unavailable, Sensor is sensorname.

or

Failed to obtain data of the arg1 voltage for PIC card arg2.

This alarm is generated when the system failed to obtain the PIC card voltage.

This alarm is generated by the following sensors:

Mngmnt Health

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2800FFFF

Minor

Yes

Parameters

Name

Meaning

sensorname

For example, PICN SYS 1V, PICN SYS 1.2V, PICN SYS 1.25V, PICN SYS 1.8V, PICN SYS 3.3V, and PICN SYS 12V.

arg1

Voltage detection point. For example, SYS 1V8 or SYS 1V25.

arg2

Slot number of the PIC card.

Impact on the System

The voltage cannot be monitored. No alarm will be reported when the voltage is not in the normal range.

Possible Causes

  • The BMC does not work normally.
  • The PIC card does not work normally.

Procedure

  1. Restart the BMC of the switch module. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 2.

    You can restart the BMC using either of the following method:

    On the HMM CLI, run the telnet 0 1101 command, switch to the BMC CLI, and run the ipmcset -d reset command.

  2. Reseat the switch module. Then check whether the alarm is cleared..

    • If yes, no further action is required.
    • If no, go to 3.

  3. Replace the PIC card. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 4.

  4. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  5. Contact Huawei technical support.
Translation
Download
Updated: 2018-08-16

Document ID: EDOC1000015902

Views: 195949

Downloads: 1571

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next