E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Slot: Failed to Read Mezzanine Card FRU Data (Minor, Mngmnt Health)

Slot: Failed to Read Mezzanine Card FRU Data (Minor, Mngmnt Health)

Description

Alarm message:

FRU failure

or

Failed to obtain electronic label data of the mezzanine card arg1.

This alarm is generated when the system failed to obtain the electronic label data of mezzanine card.

This alarm is generated by the following sensors:

Mngmnt Health

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2805FFFF

Minor

Yes

Parameters

Name

Meaning

arg1

Serial number of the mezzanine card, for example, 1 or 2.

Impact on the System

The system cannot obtain mezzanine card asset information.

Possible Causes

  • The iBMC is abnormal.
  • The electronic label data of mezzanine card is damaged.

Procedure

  1. Restart the iBMC. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 2.
    You can restart the iBMC using either of the following methods:
    • On the HMM CLI, run the telnet 0 1101 command, switch to the iBMC, and run the ipmcset -d reset command.
    • On the HMM WebUI, choose Chassis settings > Network Settings > Node, switch to the iBMC WebUI, choose System > Firmware Upgrade, and click Restart iBMC.

  2. Reseat the compute node and then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Replace the mezzanine card. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 4.

  4. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  5. Contact Huawei technical support.