E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MM: FRU Inactive (Major, Backup Unit)

MM: FRU Inactive (Major, Backup Unit)

Description

Alarm message:

FRU inactive

This alarm is generated when the active MM910 detects that the standby MM910 is unhealthy.

This alarm is generated by the following sensor:

Backup Unit

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2C01FFFF

Major

Yes

Impact on the System

The device management software may operate abnormally after an active/standby switchover.

Possible Causes

  • The hardware is faulty.
  • The device management software is abnormal.

Procedure

  1. Find out the static IP address of the standby MM910 by referring to the network plan.
  2. Check whether you can log in to the CLI of the standby MM910.

    • If yes, go to 3.
    • If no, go to 6.

  3. Run the ifconfig command and record the IP addresses and subnet masks of eth1 and eth2 of the standby MM910.
  4. Use the same method to record the IP addresses and subnet masks of eth1 and eth2 of the active MM910. Check whether the IP addresses of eth1 and eth2 of the two MM910 modules are on the same network segment.

    • If yes, go to 6.
    • If no, go to 5.

  5. On the CLI of the standby MM910, run the reboot command. After the restart is complete, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

  6. Connect to the standby MM910 through the serial port, collect serial port logs for ten minutes, and contact technical support.
  7. Contact Huawei technical support.