E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Fan: Abnormal Hot Swap Status (Minor, FRU Hot Swap)

Fan: Abnormal Hot Swap Status (Minor, FRU Hot Swap)

Description

Alarm message:

Transition to M7

This alarm is generated when the hot swap status of the fan module transits to M7 and the communication is disconnected.

This alarm is generated by the following sensors:

FRU Hot Swap

Attribute

Alarm ID

Alarm Severity

Auto Clear

0xF007FFFF

Minor

Yes

Impact on the System

The data transmission between the fan module and the MM910 is affected.

Possible Causes

The fan module is removed incorrectly.

Procedure

  1. Reinstall the fan module. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 2.

  2. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  3. Contact Huawei technical support.