E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DRIVER

DRIVER

DRIVER_1.3.6.1.4.1.2011.5.25.219.2.2.8 hwBoardBecomeMaster

Description

Board changed to the master state. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=[EntityTrapFaultID],Reason=Master/Slave Board Switchover.)

The standby device became the active device.

Attribute

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.8

Trap severity

Warning

Parameters

Name

Meaning

EntityPhysicalIndex

Indicates the index of an entity.

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityType

Indicates the entity type.

EntityTrapFaultID

Indicates the error code: 133120.

Reason

Indicates a possible cause.

Impact on the System

If no active/standby switchover is performed, the active device may be faulty.

Possible Causes

The master/slave switchover was performed or the active device was faulty.

Procedure
  1. Check whether active/standby switchover was performed.
    • If so, no action is required.
    • If not, go to step 2.
  2. Run the display device [ slot slot-id ] command to check whether the original active device has been registered successfully.
    • If so, go to step 4.
    • If not, go to step 3.
  3. Remove and install the original active device. After the device is started successfully, check whether the device is registered successfully.
    • If so, go to step 4.
    • If not, go to step 5.
  4. Check whether the original active device is faulty. Perform master/slave switchover to check whether the active/standby switchover can be performed.
    • If so, go to step 6.
    • If not, go to step 5.
  5. Collect traps, logs, and configurations, and contact Huawei technical support engineers.