E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITY-TRAP

ENTITY-TRAP

SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.1 hwSystemConfigError

Description

A system configuration error occurs. ( EntityTrapFaultID = [EntityTrapFaultID])

The system configuration was incorrect.

Attributes

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.11.1

Trap severity

Critical

Match trap

SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.2 hwSystemConfigResume

Parameters

Parameter

Description

EntityTrapFaultID

Trap error codes.

  • EntityTrapFaultID=144130 indicates that the package versions of the master and slave boards were inconsistent.
Impact on the System

The slave board cannot be activated when the package versions of the master and slave boards are inconsistent.

Possible Causes

The package versions of the master and slave boards were inconsistent.

Procedure
  1. Run the startup system-software system-file [ all | slave-board | slot slot-id ] command to configure the slave board version to be consistent with the master board version. Run the reset command to reset the slave board. Wait for a period of time, and then check whether the alarm is cleared.
  • If yes, go to Step 3.
  • If No, go to Step 2.
  1. Collect the alarm information, log information, and configuration information, and then contact Huawei technical support personnel.
  2. End.

SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.2 hwSystemConfigResume

Description

The system configuration error has been rectified. ( EntityTrapFaultID = [EntityTrapFaultID])

The system configuration was corrected.

Attributes

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.11.2

Trap severity

Warning

Match trap

SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.1 hwSystemConfigError

Parameters

Parameter

Description

EntityTrapFaultID

Trap error codes.

  • EntityTrapFaultID=144130 indicates that the package versions of the master and slave boards were inconsistent.
Impact on the System

Services are not affected.

Possible Causes

Cause 1: The package versions of the master and slave boards changed from being inconsistent to being consistent.

Cause 2: The versions of the PAF and startup package changed from being inconsistent to being consistent.

Procedure
  • This alarm message is informational only, and no action is required.