E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFMTRUNK

IFMTRUNK

IFMTRUNK_1.3.6.1.4.1.2011.5.25.41.3.30 hwTrunkMemNumberChange

Description

The number of active trunk members changed.(TrunkName=[TrunkName],PortName=[PortName],ActiveTrunkMemNum=[TrunkMemNumber],Reason=[Reason])

The number of active trunk member interfaces changed.

Attribute

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.41.3.30

Trap severity

Notice

Parameters

Parameter

Description

TrunkName

Name of the trunk interface

PortName

Name of the trunk member interface

ActiveTrunkMemNum

Number of active trunk member interfaces

Reason

Reason

Impact on the System

None.

Possible Causes

Cause 1: A trunk member interface went Up.

Cause 2: A trunk member interface went Down.

Procedure
  • Cause 1: A trunk member interface went Up.
    • This trap message is informational only, and no action is required.
  • Cause 2: A trunk member interface went Down.
    • If a trunk member interface went Down, check if there is an IFMCOMM_1.3.6.1.6.3.1.1.5.3 linkDown alarm on the trunk member interface and find out the alarm cause.