E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SNMP

SNMP

SNMP_1.3.6.1.6.3.1.1.5.1 coldStart

Description

OID [oidname] coldStart.

The device was cold started.

Attributes

Attribute

Description

Trap OID

1.3.6.1.6.3.1.1.5.1

Trap Severity

Warning

Parameters

Parameter

Description

oidname

OID name of an object

VSID

Indicates the VS identifier.

Impact on the System

Services are not affected.

Possible Causes

The system restarted because of power-off.

Procedure
  • The system restarted because of power-off.
    1. Check whether the power cables are installed properly.
      • If the power cables are installed properly, go to Step 2.
      • If the power cables are installed improperly, install the power cables properly.
    2. Check whether the device is restarted by the maintenance personnel.
      • If the device is restarted by the maintenance personnel, no action is required.
      • If the device is not restarted by the maintenance personnel, go to Step 3.
    3. Check whether the power supply system is working stably.
      • If the power supply system is working stably, go to Step 4.
      • If the power supply system is not working stably, contact engineers of the power supply department.
    4. Collect the alarm information, log information, and configurations, and then contact the Huawei technical support personnel.

SNMP_1.3.6.1.6.3.1.1.5.2 warmStart

Description

OID [oidname] warmStart

The device was hot started.

Attributes

Attribute

Description

Trap OID

1.3.6.1.6.3.1.1.5.2

Trap Severity

Warning

Parameters

Parameter

Description

oidname

OID name of an object

Impact on the System

Services are not affected.

Possible Causes

Cause: The device was hot started.

Procedure
  • This trap message is informational only, and no action is required.

SNMP_1.3.6.1.6.3.1.1.5.5 authenticationFailure

Description

Failed to login through SNMP.(IPAddress=[IPAddress],CommunityName/UserName=[CommunityName/UserName], ReasonInfo=[ReasonInfo].)

SNMP authentication failed.

Attributes

Attribute

Description

Trap OID

1.3.6.1.6.3.1.1.5.5

Trap Severity

Warning

Parameters

Parameter

Description

IPAddress

User IP address

CommunityName/UserName

Community name or USM user name

ReasonInfo

Cause of a login failure

Impact on the System

Services are not affected.

Possible Causes

The SNMP login failed because of an incorrect community name or user name.

Procedure
  • The log is informational only, and no action is required.