E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-1.3.6.1.4.1.2011.2.82.1.150.1.1.2.10 FC Link Failure

ALM-1.3.6.1.4.1.2011.2.82.1.150.1.1.2.10 FC Link Failure

Description

1. The fiber channel (FC) optical module cannot be detected or is not properly installed. 2. The optical fiber of the link is not securely inserted. 3. The FC optical module is faulty. 4. The peer link is faulty.

Attribute

Alarm ID

Alarm Severity

Alarm Type

1.3.6.1.4.1.2011.2.82.1.150.1.1.2.10

Minor

Fault alarm

Parameters

Name

Meaning

shelfName

Indicates the number of the chassis for which the alarm is generated.

SlotIndex

Indicates the slot number of the board for which the alarm is generated.

TrapInfo

Indicates the meaning of the alarm parameters.

Impact on the System

The service processing is affected.

Possible Causes

  • The FC optical module cannot be detected or is not properly installed.
  • The optical fiber is not securely inserted.
  • The FC optical module is faulty.
  • The peer link is faulty.

Procedure

  1. Check whether the local and peer optical fibers and FC optical modules are intact and installed correctly.

  1. Remove and reinstall or replace the optical fibers and FC optical modules. Then check whether the link indicators of the FC optical modules are on.

    • If yes, no further action is required.
    • If no, contact Huawei technical support for help or submit a fault report at http://iCare.huawei.com.

Clearing

This alarm is cleared when the system detects that the FC link is operating properly.

After the fault is rectified, the system automatically clears the alarm.