E9000 Server V100R001 HMM Alarm Handling 19

This document describes E9000 server alarms in terms of the meaning, impact on the system, possible causes, and solutions.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EFM

EFM

EFM_1.3.6.1.4.1.2011.5.25.136.1.6.5 hwDot3ahEfmNonThresholdEvent

Description

OID [oid] Nonthreshold Event occured. (IfIndex=[INTEGER], EventLogIndex=[GAUGE], EventLogTimestamp=[TIMETICK], EventLogOUI=[OPAQUE], EventLogType=[GAUGE], EventLogLocation=[INTEGER])

None-threshold-crossing events occur on the link, including LinkLost, LinkFault and DyingGasp.

Attributes

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.136.1.6.5

Trap Severity

Minor

Match Trap

EFM_1.3.6.1.4.1.2011.5.25.136.1.6.17 hwDot3ahEfmNonThresholdRecovery

Parameters

Parameter

Description

oid

Indicates the ID of the MIB object.

IfIndex

Indicates the interface index.

EventLogIndex

Indicates the index of the printed log.

EventLogTimestamp

Indicates the time stamp that records when the event occurs.

EventLogOUI

Indicates the OUI of an event.

EventLogType

Indicates the type of an event.

EventLogLocation

Indicates where the event occurs, on the local end or the remote end.

Impact on the System

Services will be interrupted.

Possible Causes

Cause 1:

The remote interface was not enabled with EFM.

Cause 2:

The interface was shut down; or the physical link went Down.

Cause 3:

The local or remote device was restarted.

Procedure
  1. Check the value of the EventLogType field in the trap:
  • 254: indicates the timeout. Then, go to Step 2.
  • 256: indicates that the local interface is shut down. Then, go to Step 3.
  • 257: indicates the DyingGasp event. Then, go to Step 4.
  1. Run the display this command in the interface view to check whether EFM is enabled on the remote device.

    • If so, go to Step 5.
    • If not, go to Step 6.

  2. Run the display this command in the interface view to check whether the local interface is shut down.

    • If so, go to Step 7.
    • If not, go to Step 5.

  3. Check whether the remote device is being restarted.

    • If so, go to Step 8.
    • If not, go to Step 10.

  4. Check whether the physical link is faulty.

    • If so, go to Step 9.
    • If not, go to Step 10.

  5. Run the efm enable command in the interface view of the remote device to enable EFM. Then, check whether the alarm is cleared.

    • If so, go to Step 11.
    • If not, go to Step 10.

  6. Run the undo shutdown command in the interface view to check whether the alarm is cleared.

    • If so, go to Step 11.
    • If not, go to Step 5.

  7. After the remote device works normally, check whether the alarm is cleared.

    • If so, go to Step 11.
    • If not, go to Step 10.

  8. Replace the physical link and then check whether the alarm is cleared.

    • If so, go to Step 11.
    • If not, go to Step 10.

  9. Collect trap messages, log messages, and configurations, and then contact the Huawei technical support personnel.
  10. End.

EFM_1.3.6.1.4.1.2011.5.25.136.1.6.17 hwDot3ahEfmNonThresholdRecovery

Description

OID [OID] Nonthreshold trap recovered. (IfIndex=[INTEGER], EventLogIndex=[GAUGE], EventLogTimestamp=[TIMETICK], TrapLogOUI=[OPAQUE], TrapLogType=[GAUGE], TrapLogLocation=[INTEGER])

The trap about handshake timeout or a link event was cleared.

The trap about handshake timeout, a link event, or DyingGasp was cleared.

Attributes

Attribute

Description

Trap OID

1.3.6.1.4.1.2011.5.25.136.1.6.17

Trap Severity

Minor

Match Trap

EFM_1.3.6.1.4.1.2011.5.25.136.1.6.5 hwDot3ahEfmNonThresholdEvent

Parameters

Parameter

Description

oid

Indicates the ID of the MIB object.

IfIndex

Indicates the interface index.

EventLogIndex

Indicates the index of the printed log.

EventLogTimestamp

Indicates the time stamp that records when the event occurs.

TrapLogOUI

Indicates the OUI of an event.

TrapLogType

Indicates the type of an event.

TrapLogLocation

Indicates where the event occurs, on the local end or the remote end.

Impact on the System

The system performance is not affected.

Possible Causes

The trap about handshake timeout, a link event, an urgent event, or a remote fault was cleared.

Procedure
  • This trap message is informational only, and no action is required.
Translation